筛查乳腺X线摄影中检出的微钙化:合成乳腺X线摄影联合数字乳腺断层合成与数字乳腺X线摄影的比较
本回顾性多阅片者观察研究纳入72例因微钙化被召回的筛查乳腺X线摄影(54例良性、18例恶性)及20例无微钙化对照,比较FFDM与SM联合DBT对微钙化的检出效能。FFDM与SM+DBT的阅片者间一致性kappa值分别为0.66和0.63;FFDM对全部微钙化的合并敏感度80%、对恶性微钙化92%,SM+DBT分别为75%和94%;FFDM特异度98%、SM+DBT 95%。混合效应模型显示两种方法间无差异(−0.03;95%CI:−0.08,0.01;P=0.13)。
要点
- FFDM与SM+DBT对筛查召回微钙化的敏感度和特异度相似,混合效应模型示两种方法间无差异(P=0.13)。
- 对恶性微钙化,FFDM合并敏感度92%(66/72),SM+DBT为94%(68/72)。
- 阅片者间一致性FFDM kappa值0.66、SM+DBT 0.63(均P<.001)。
核心结论
- 相对于全视野数字乳腺X线摄影,合成乳腺X线摄影联合数字乳腺断层合成对筛查乳腺X线摄影中先前已识别需召回的微钙化具有相似的敏感度和特异度。
研究设计与样本
- 回顾性多阅片者观察研究,纳入2015年6月至2016年8月连续72例因微钙化被召回的筛查乳腺X线摄影(54例良性微钙化、18例恶性微钙化),另加20例无微钙化筛查乳腺X线摄影作为对照。
- 四位阅片者独立审阅每个数据集,比较FFDM单独与合成乳腺X线摄影联合DBT,并计算微钙化检出的敏感度和特异度及Fleiss kappa阅片者间一致性。
诊断标准与关键数值
- FFDM对全部微钙化的合并敏感度80%(229/288;95%CI:74%,84%),对恶性微钙化92%(66/72;95%CI:83%,97%)。
- SM+DBT对全部微钙化的合并敏感度75%(215/288;95%CI:69%,80%),对恶性微钙化94%(68/72;95%CI:86%,98%)。
- FFDM对全部微钙化和对恶性微钙化的合并特异度均为98%(78/80;95%CI:91%,100%)。
- SM+DBT对全部微钙化和对恶性微钙化的合并特异度均为95%(76/80;95%CI:88%,99%)。
- 混合效应模型结论为两种方法间无差异(−0.03;95%CI:−0.08,0.01;P=0.13)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare the performance of two-dimensional synthetic mammography (SM) plus digital breast tomosynthesis (DBT) versus conventional full-field digital mammography (FFDM) in the detection of microcalcifications on screening mammograms. Materials and Methods In this retrospective multireader observer study, 72 consecutive screening mammograms recalled for microcalcifications from June 2015 through August 2016 were evaluated with both FFDM and DBT. The data set included 54 mammograms with benign microcalcifications and 18 mammograms with malignant microcalcifications, and 20 additional screening mammograms without microcalcifications used as controls. FFDM alone was compared to synthetic mammography plus DBT. Four readers independently reviewed each data set and microcalcification recalls were tabulated. Sensitivity and specificity for microcalcification detection were calculated for SM plus DBT and for FFDM alone. Interreader agreement was calculated with Fleiss kappa values. Results Reader agreement was kappa value of 0.66 (P < .001) for FFDM and 0.63 (P < .001) for SM plus DBT. For FFDM, the combined reader sensitivity for all microcalcifications was 80% (229 of 288; 95% confidence interval [CI]: 74%, 84%) and for malignant microcalcifications was 92% (66 of 72; 95% CI: 83%, 97%). For SM plus DBT, the combined reader sensitivity for all microcalcifications was 75% (215 of 288; 95% CI: 69%, 80%) and for malignant microcalcifications was 94% (68 of 72; 95% CI: 86%, 98%). For FFDM, the combined reader specificity for all microcalcifications was 98% (78 of 80; 95% CI: 91%, 100%) and for malignant microcalcifications was 98% (78 of 80; 95% CI: 91%, 100%). For SM plus DBT, combined reader specificity for all microcalcifications was 95% (76 of 80; 95% CI: 88%, 99%) and for malignant microcalcifications was 95% (76 of 80; 95% CI: 88%, 99%). Mixed-effects model concluded no differences between modalities (‒0.03; 95% CI: ‒0.08, 0.01; P = .13). Conclusion Relative to full-field digital mammography, synthetic mammography plus digital breast tomosynthesis had similar sensitivity and specificity for the detection of microcalcifications previously identified for recall at screening mammography. © RSNA, 2018 See also the editorial by Bae and Moon in this issue.