超声引导下经皮真空辅助旋切良性乳腺病灶:评估结局的学习曲线
回顾性纳入143例患者共152次超声引导下真空辅助旋切(US-VAE),初次完全切除率90.8%,6个月随访完全切除率72%;无残留病灶的平均最大径16.9 mm、体积1.53 cm³,有残留者分别为21.9 mm、3.39 cm³(P均<0.001);病灶体积阈值2.6 cm³(特异度84.5%)与无残留相关,完全切除的学习曲线平均需11次操作。
要点
- 初次完全切除率90.8%(138/152),6个月随访完全切除率72%(100/143)。
- 无残留病灶平均最大径16.9 mm、体积1.53 cm³,有残留者21.9 mm、3.39 cm³(P均<0.001)。
- 病灶体积2.6 cm³为无残留的ROC阈值(特异度84.5%),体积增大与疗效降低相关。
核心结论
- 超声引导下真空辅助旋切是良性乳腺病灶的有效治疗方法,评估经皮治疗时应考虑病灶体积。
研究设计与样本
- 回顾性研究,经机构审查委员会批准;纳入143例患者共152次超声引导下真空辅助旋切,术后6个月行超声和临床随访,采用累积和(CUSUM)图评估完全切除与血肿的学习曲线。
关键影像表现/征象
- 无残留病灶的平均最大径为16.9 mm,有残留病灶为21.9 mm(P<0.001)。
- 无残留病灶的平均体积为1.53 cm³,有残留病灶为3.39 cm³(P<0.001)。
诊断标准与关键数值
- 初次完全切除率为90.8%(138/152)。
- 6个月随访完全切除率为72%(100/143)。
- ROC分析显示无残留病灶的体积阈值为2.6 cm³(r=0.71,特异度84.5%)。
- CUSUM图显示平均需11次旋切才能在操作结束时完全切除率超过80%,6个月时需18次。
临床应用与阅片要点
- 病灶体积增大与疗效降低(P=0.05)、临床控制降低(P=0.05)及临床显著血肿风险增高(P=0.05)相关。
- 作者认为评估经皮治疗时应考虑乳腺病灶体积。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: To evaluate the efficacy and learning curve of ultrasoundguided vacuum-assisted excision (US-VAE) of benign breast lesions, and to assess characteristics associated with residual lesion.
METHODS:: This was a retrospective study with institutional review board-approval. Sonographic and clinical follow-up were performed 6 months after intervention. Effectiveness and safety of the technique were analyzed. The cumulative summation (CUSUM) graphs were used to evaluate learning curves concerning complete excision and hematoma.
RESULTS:: 152 ultrasound-VAEs in 143 patients were included. Initial complete resection was achieved in 90.8 % (138 of 152). 6-month follow-up was completed for 143 (94%) of cases and complete resection was observed in 72 % (100 of 143). Mean maximum size without residual tumor was 16.9 mm, while with residual lesion it was 21.9 mm (p = < 0.001), with a volume of 1.53 and 3.39 cm3, respectively (p = < 0.001). Increase in lesion size and volume was associated with less effectiveness (p = 0.05), clinical control (p = 0.05), and higher risk of clinically significant hematoma (p = 0.05). Receiver operating characteristic analysis demonstrate a volume threshold of 2.6 cm3 (r = 0.71, specificity 84.5%) for leaving no residual lesion. Cumulative summation graphs demonstrate that, on average, 11 excisions were required to acquire skills to perform complete excision in more than 80% at the end of the ultrasound-VAE and 18 excisions at 6 months.
CONCLUSION:: Ultrasound-VAE is an effective treatment for benign breast lesions. Breast lesion volume should be considered when assessing for percutaneous treatment.
ADVANCES IN KNOWLEDGE:: A follow-up of the learning process of ultrasound-VAE will be a valuable tool to assess the efectiveness and safety of the technique i.
引用
- Salazar JP, Miranda I, de Torres J, et al. Percutaneous ultrasound-guided vacuum-assisted excision of benign breast lesions: A learning curve to assess outcomes. Br J Radiol. 2018. PMID: 30359092. doi:10.1259/bjr.20180626
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。