文献速递儿科影像神经MR

3-T胎儿MRI是否会对新生儿产生不良声学影响?一项比较1.5 T与3 T扫描胎儿出生后听力测试表现的初步研究

Does 3-T fetal MRI induce adverse acoustic effects in the neonate? A preliminary study comparing postnatal auditory test performance of fetuses scanned at 1.5 and 3 T.
PubMed 文献 · Pediatr Radiol · 2018-10-08

该回顾性研究纳入2012至2016年接受3-T胎儿MRI并在出生后60天内完成普遍新生儿听力筛查的62例新生儿,并按相同排除标准随机选取62例1.5-T胎儿MRI新生儿为对照。3-T组瞬态诱发性耳声发射测试未通过率为6.5%、听性脑干反应测试未通过率为1.6%,1.5-T组分别为9.7%和3.2%,两组比较均无显著差异(P=0.74和P=0.8)。作者认为,3 T相关的噪声增加并未提高临床可检出听力异常的发生率。

要点

  • 3-T组瞬态诱发性耳声发射未通过率6.5%,1.5-T组9.7%,两组无显著差异(P=0.74)。
  • 3-T组听性脑干反应未通过率1.6%,1.5-T组3.2%,两组无显著差异(P=0.8)。
  • 3-T组中位孕龄30周1天,显著高于1.5-T组的20周2天(P<0.001)。

核心结论

  • 研究结果表明,3 T相关的噪声增加并未提高临床可检出听力异常的发生率。

研究设计与样本

  • 回顾性研究,2012至2016年接受3-T胎儿MRI者340例中62例符合纳入标准,另按相同排除标准从1.5-T胎儿MRI合格人群中随机选取62例为对照。
  • 纳入者均在出生后60天内完成普遍新生儿听力筛查;排除听力筛查不完整、两种场强均做过MRI或患有与听力损失相关疾病者。
  • 5例受试者接受了同场强重复MRI(3 T组1例,1.5 T组4例)。
  • 采用Fisher精确检验比较瞬态诱发性耳声发射测试与听性脑干反应测试的通过/未通过率,并行逻辑回归评估其他已知先天性听力损失危险因素的影响。

诊断标准与关键数值

  • 3-T组瞬态诱发性耳声发射测试未通过率6.5%,1.5-T组9.7%,两组无显著差异(P=0.74)。
  • 3-T组听性脑干反应测试未通过率1.6%,1.5-T组3.2%,两组无显著差异(P=0.8)。
  • 3-T组中位孕龄30周1天,显著高于1.5-T组的中位孕龄20周2天(P<0.001)。

临床应用与阅片要点

  • 作者认为,3 T相关的噪声增加并未提高临床可检出听力异常的发生率。

局限性

  • 原文标题标明为初步研究。
  • 3-T组中位孕龄30周1天显著高于1.5-T组的20周2天(P<0.001),两组孕龄存在差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Fetal MRI at 3 T is associated with increased acoustic noise relative to 1.5 T.

OBJECTIVE: The goal of this study is to determine if there is an increased prevalence of congenital hearing loss in neonates who had a 3-T prenatal MR vs. those who had it at 1.5 T.

MATERIALS AND METHODS: We retrospectively identified all subjects who had 3-T fetal MRI between 2012 and 2016 and also underwent universal neonatal hearing screening within 60 days of birth. Fetuses with incomplete hearing screening, magnetic resonance imaging (MRI) studies at both field strengths or fetuses affected by conditions associated with hearing loss were excluded. A random group of controls scanned at 1.5 T was identified. Five subjects had repeat same-strength MRIs (one at 3 T and four at 1.5 T). The pass/fail rate of the transient otoacoustic emissions test and auditory brainstem response test were compared using the Fisher exact test. A logistic regression was performed to assess the effects of other known risk factors for congenital hearing loss.

RESULTS: Three hundred forty fetal MRI examinations were performed at 3 T, of which 62 met inclusion criteria. A control population of 1.5-T fetal MRI patients was created using the same exclusion criteria, with 62 patients randomly selected from the eligible population. The fail rates of transient otoacoustic emissions test for the 1.5-T and 3-T groups were 9.7% and 6.5%, respectively, and for the auditory brainstem response test were 3.2% and 1.6%, respectively. There was no significant difference in the fail rate of either test between groups (P=0.74 for transient otoacoustic emissions test, and P=0.8 for auditory brainstem response test). The median gestational age of the 3-T group was 30 weeks, 1 day, significantly higher (P<0.001) than the 1.5-T group (median gestational age: 20 weeks, 2 days).

CONCLUSION: Our findings suggest that the increase in noise associated with 3 T does not increase the rate of clinically detectable hearing abnormalities.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Jaimes C, Delgado J, Cunnane MB, et al. Does 3-T fetal MRI induce adverse acoustic effects in the neonate? A preliminary study comparing postnatal auditory test performance of fetuses scanned at 1.5 and 3 T. Pediatr Radiol. 2018. PMID: 30298210. doi:10.1007/s00247-018-4261-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。