文献速递妇产影像儿科影像US

一种定量二维超声分析胎儿脊髓圆锥位置的方法

A method for quantitative 2-dimensional sonographic analysis of the fetal conus medullaris position.
PubMed 文献 · J Ultrasound Med · 2018-10-07

前瞻性研究在521例20-38周胎儿中,通过识别第一骶椎(S1)定位脊髓圆锥水平并测量圆锥至S1中点距离(CM-S1),发现70%病例圆锥位于L2及L2-3水平,37周后位于L2及以上;CM-S1与孕龄显著正相关(R²=0.89,P<.05),并建立正常参考范围及第五百分位;低于第五百分位提示可能存在脊髓栓系。

要点

  • 70%胎儿脊髓圆锥位于L2和L2-3水平,37周后位于L2及以上。
  • CM-S1距离与孕龄显著正相关,R²=0.89,P<.05,最佳拟合公式为CM-S1距离=1.57×孕龄-16.43。
  • 低于对应孕龄第五百分位提示可能存在脊髓栓系。

核心结论

  • 二维超声识别S1并测量CM-S1距离可定量评估胎儿脊髓圆锥位置,CM-S1与孕龄存在显著正相关(R²=0.89,P<.05),已建立正常参考范围及第五百分位,低于第五百分位提示可能存在脊髓栓系。

研究设计与样本

  • 前瞻性研究,纳入521例孕龄20-38周胎儿,采用二维超声扫描,通过两条线交点识别第一骶椎(S1),向上计数确定脊髓圆锥水平,并记录骨化骶椎体数目,测量脊髓圆锥至S1中点距离(CM-S1),以孕龄为参照分析相关性并建立正常参考范围及第五百分位。

关键影像表现/征象

  • 通过两条线交点识别S1,再向上计数可确定脊髓圆锥水平。
  • 70%病例脊髓圆锥位于L2和L2-3水平,37周后位于L2及以上。
  • 骨化骶椎体数目不一致。
  • CM-S1测量容易操作。

诊断标准与关键数值

  • CM-S1距离与孕龄显著正相关(R²=0.89,P<.05),最佳拟合公式为CM-S1距离=1.57×孕龄-16.43。
  • 已建立正常参考范围并计算各孕龄第五百分位,低于第五百分位提示可能存在脊髓栓系。

临床应用与阅片要点

  • 在二维超声上先通过两条线交点识别S1,再向上计数确定脊髓圆锥水平并记录骨化骶椎体数目。
  • 测量脊髓圆锥至S1中点距离(CM-S1)并与对应孕龄第五百分位比较,低于第五百分位提示可能存在脊髓栓系。

局限性

  • 原文在结论中提出低于第五百分位提示可能存在脊髓栓系,未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study explored the use of 2-dimensional (2D) ultrasound scans for the quantitative assessment of the fetal conus medullaris (CM) position and its correlation with gestational age (GA).

METHODS: This was a prospective study. We identified the first sacral vertebra (S1) by intersection of 2 lines in 2D scans, then counted upward from S1 to determine the CM level and recorded the number of ossified sacral vertebral bodies. A quantitative assessment of the CM position was performed by measuring the distance between the CM and the midpoint of the S1 (CM-S1). The correlation between the CM-S1 distance and GA was evaluated.

RESULTS: We determined the CM level by identifying S1 first in 521 fetuses (GA, 20-38 weeks). The CM position in 70% of cases was at the L2 and L2-3 level, and at the L2 level or above after 37 weeks. The number of ossified sacral veterbral bodies was not consistent. CM-S1 measurements were easy to perform. A significant positive correlation between CM-S1 distance and GA was observed (R2 = .89, P < .05). The best-fit formula was: CM-S1 distance = 1.57 × GA - 16.43. The normal reference range was established and the fifth percentile was calculated for each GA.

CONCLUSIONS: S1 was easily identified, and the CM position relative to S1 was useful. There was a substantial correlation between CM-S1 and GA. Below the fifth percentile it was suggested that tethered cord may exist.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhai J, Cai A, Wei Q, et al. A method for quantitative 2-dimensional sonographic analysis of the fetal conus medullaris position. J Ultrasound Med. 2018. PMID: 30294797. doi:10.1002/jum.14771

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。