PubMed 文献 · Eur J Radiol · 2018-09-01

回顾性纳入61例临床怀疑前列腺癌患者,在3 T下比较b值2000 s/mm²缩减视野DWI与常规DWI的图像质量,并对32例有详细病理报告者用PI-RADS v2分析诊断效能。缩减视野DWI图像质量定性评分及外周带、移行带ADC对比均显著更优,肿瘤检出率、敏感度和AUC更高,常规DWI特异度略高但多数无显著差异。

要点

  • 缩减视野DWI在b值2000 s/mm²下图像质量定性评分显著优于常规DWI(所有P<0.05)。
  • 缩减视野DWI的外周带和移行带ADC对比评分显著高于常规DWI(P=0.001和P=0.003)。
  • 缩减视野DWI的肿瘤检出率、敏感度和AUC高于常规DWI(均P<0.05),仅一名读者外周带AUC除外(P=0.262)。

核心结论

  • 缩减视野DWI可提供更优图像质量,相比常规序列在前列腺癌中肿瘤检出率更高、分期相对精确,诊断效能更好。

研究设计与样本

  • 回顾性招募61例临床怀疑前列腺癌患者,均行3 T缩减视野DWI和常规DWI;图像质量由两名盲法放射科医生定性及定量评估,其中32例有详细病理报告者用PI-RADS v2进一步分析诊断效能。

关键影像表现/征象

  • 缩减视野DWI的图像质量定性评估显著优于常规DWI(所有P<0.05)。
  • 缩减视野DWI的外周带ADC对比评分显著高于常规DWI(P=0.001),移行带亦显著高于常规DWI(P=0.003)。

诊断标准与关键数值

  • 诊断效能分析采用PI-RADS第2版,比较缩减视野DWI与常规DWI的肿瘤检出率、敏感度、特异度、AUC及PI-RADS分期变化。
  • 缩减视野DWI的肿瘤检出率、敏感度和AUC高于常规DWI(均P<0.05),但一名读者外周带AUC除外(P=0.262)。
  • 常规DWI在外周带和移行带的特异度略高于缩减视野DWI,除一名读者外周带外(P=0.009)无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare high b value (2000 s/mm2) reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with a conventional DWI sequence in terms of image quality, as well as diagnostic performance concerning prostate cancer (PCa) detection and tumor staging at 3 T.

METHODS: Sixty-one patients underwent rFOV DWI and conventional DWI due to clinical suspicious of PCa were retrospectively recruited. Imaging qualities were evaluated qualitatively and quantitatively by two blinded radiologists. Thirty-two subjects with detailed pathology reports were further analyzed for diagnostic efficacy using the Prostate Imaging Reporting and Data System (PI-RADS) version 2. The PCa detection rate, sensitivity, specificity, and PI-RADS staging changes were compared between the DWI sequences.

RESULTS: Qualitative evaluation regarding image quality was significantly better in rFOV DWI than in the conventional DWI (all P < 0.05). ADC contrast with rFOV DWI was rated significantly higher than the conventional DWI in both peripheral zone (PZ) and transition zone (TZ) (P = 0.001 for PZ, and P = 0.003 for TZ). Regarding diagnostic efficacy, rFOV DWI yielded higher tumor detection, sensitivity and the area under the curve (AUC) than the conventional DWI (all P < 0.05), except the AUC in the PZ for one reader (P = 0.262). Conventional DWI achieved slightly higher specificity for the PZ and TZ but with no significant difference except for one reader in the PZ (P = 0.009).

CONCLUSION: The rFOV DWI could offer improved image quality and yielded better diagnostic performance in terms of higher tumor detection rate and relatively precise staging for PCa compared to the conventional sequence.

来源:Eur J Radiol,查看原文。版权归原作者所有。