前瞻性评估锡滤过超低剂量100千伏对比增强腹部CT:对辐射剂量降低和图像质量的影响(第三代双源CT系统)
前瞻性纳入93例需行单期增强腹盆部CT的患者,在标准协议外追加锡滤过100千伏单能采集,比较辐射剂量、图像质量和诊断信心。锡滤过协议平均剂量显著更低(CDTI 1.56 vs 8.13 mGy,SSDE 9.94 vs 1.93,有效剂量约1.14 mSv),肝脏CNR无显著差异(2.76 vs 3.03,p=0.56),FOM更高(10.6 vs 2.49/mSv),内脏、骨和腹膜肿瘤诊断信心相当,辐射剂量降低81%。
要点
- 锡滤过100千伏协议有效剂量约1.14 mSv,较标准协议降低81%。
- 肝脏CNR两组无显著差异(2.76 vs 3.03,p=0.56)。
- 内脏、骨和腹膜肿瘤诊断信心两组相当。
核心结论
- 锡滤过100千伏增强腹盆部CT可获得与标准CT协议相似的诊断性能和CNR,同时辐射剂量降低81%。
研究设计与样本
- 前瞻性研究,连续纳入93例需行单期增强腹盆部CT的患者,在标准协议外追加锡滤过采集;均使用第三代双源CT系统单能模式、自动管电流调制、相同螺距和相同迭代重建级别;比较辐射指标、SSDE、CNR和FOM,并由两名独立阅片者评估预定腹部病变的诊断信心。
诊断标准与关键数值
- 锡滤过协议 vs 标准协议:CDTI 1.56 ± 0.43 mGy vs 8.13 ± 3.32 mGy(p < 0.001);SSDE 9.94 ± 3.08 vs 1.93 ± 0.39(p < 0.001);有效剂量约1.14 mSv ± 0.34(p < 0.001);肝脏CNR 2.76 vs 3.03(p = 0.56,无显著差异);FOM 10.6 vs 2.49/mSv(p < 0.001)。
临床应用与阅片要点
- 作者结论认为,锡滤过100千伏增强腹盆部CT在降低辐射剂量81%的同时可获得与标准协议相似的诊断性能和CNR;内脏、骨和腹膜肿瘤的诊断信心两组相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the radiation dose exposure, image quality, and diagnostic performance of enhanced 100-kVp abdominopelvic single-energy CT protocol with tin filter (TF).
METHODS: Ninety-three consecutive patients referred for a single-phase enhanced abdominopelvic CT were prospectively included after informed consent. They underwent in addition to a standard protocol (SP) an acquisition with TF. Both examinations were performed on a third-generation dual-source CT system (DSCT), in single energy, using automatic tube current modulation, identical pitch, and identical level of iterative reconstruction. Radiation metrics were compared. Size-specific dose estimates (SSDE), contrast to noise ratio (CNR), and figure of merit (FOM) were calculated. Diagnostic confidence for the assessment of a predetermined list of abdominal lesions was rated by two independent readers.
RESULTS: The mean dose of the TF protocol was significantly lower (CDTI 1.56 ± 0.43 mGy vs. 8.13 ± 3.32, p < 0.001; SSDE 9.94 ± 3.08 vs. 1.93 ± 0.39, p < 0.001), with an effective dose close to 1 mSv (1.14 mSv ± 0.34; p < 0.001). TF group exhibited non-significant lower liver CNR (2.76 vs. 3.03, p = 0.56) and was more dose efficient (FOM 10.6 vs. 2.49/mSv, p < 0.001) in comparison to SP. The mean diagnostic confidence for visceral, bone, and peritoneal tumors was equivalent between both groups.
CONCLUSIONS: Enhanced 100-kVp abdominopelvic CT acquired after spectral shaping with tin filtration can achieve similar diagnostic performance and CNR compared to a standard CT protocol, while reducing the radiation dose by 81%.
KEY POINTS: • 100-kVp spectral filtration enables enhanced abdominal CT with high-dose efficiency. • The radiation dose reaches the 1-mSv range. • Predetermined abdominopelvic lesions can be assessed without impairing on diagnostic confidence.
引用
- Leyendecker P, Faucher V, Labani A, et al. Prospective evaluation of ultra-low-dose contrast-enhanced 100-kV abdominal computed tomography with tin filter: effect on radiation dose reduction and image quality with a third-generation dual-source CT system. Eur Radiol. 2018. PMID: 30324392. doi:10.1007/s00330-018-5750-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。