应用对比增强计算机断层扫描鉴别十二指肠胃肠道间质瘤与胰头富血供胰腺神经内分泌肿瘤
研究纳入17例病理确诊的十二指肠胃肠道间质瘤和25例胰头神经内分泌肿瘤患者,分析术前对比增强CT的肿瘤大小、形态和强化特征。十二指肠胃肠道间质瘤更多表现为肿瘤中心靠近十二指肠且以实性为主,动脉期CT值更低、延迟期CT值更高。动脉期(30秒)CT值≤135 HU诊断十二指肠胃肠道间质瘤的敏感度为76%、特异度为94.1%、准确率为83.3%。
要点
- 肿瘤中心位置靠近十二指肠和以实性为主更常见于十二指肠胃肠道间质瘤(p<0.05)。
- 十二指肠胃肠道间质瘤较胰头神经内分泌肿瘤更大(3.3±0.9 cm vs. 2.5±1.1 cm,p=0.03)。
- 动脉期(30秒)CT值≤135 HU诊断十二指肠胃肠道间质瘤的敏感度为76%、特异度为94.1%、准确率为83.3%。
核心结论
- 肿瘤中心位置、大小、质地和对比增强特征有助于术前鉴别十二指肠胃肠道间质瘤与富血供胰头神经内分泌肿瘤。
研究设计与样本
- 研究纳入17例病理确诊的十二指肠胃肠道间质瘤和25例胰头神经内分泌肿瘤患者,均行术前对比增强CT,分析肿瘤大小、形态和对比增强特征,并采用受试者工作特征曲线计算截断值。
关键影像表现/征象
- 十二指肠胃肠道间质瘤较胰头神经内分泌肿瘤更多表现为肿瘤中心靠近十二指肠(p<0.05)。
- 十二指肠胃肠道间质瘤较胰头神经内分泌肿瘤更多表现为以实性为主(p<0.05)。
- 十二指肠胃肠道间质瘤较胰头神经内分泌肿瘤更大(3.3±0.9 cm vs. 2.5±1.1 cm,p=0.03)。
- 动脉期十二指肠胃肠道间质瘤CT值低于胰头神经内分泌肿瘤(112.9±17.9 HU vs. 137.4±32.1 HU,p<0.01)。
- 延迟期十二指肠胃肠道间质瘤CT值高于胰头神经内分泌肿瘤(94.3±7.9 HU vs. 84.9±10.4 HU,p<0.01)。
诊断标准与关键数值
- 动脉期(30秒)CT值≤135 HU诊断十二指肠胃肠道间质瘤的敏感度为76%、特异度为94.1%、准确率为83.3%。
- 延迟期(120秒)CT值≥89.5 HU诊断十二指肠胃肠道间质瘤的敏感度为93.3%、特异度为81.8%、准确率为76.2%。
临床应用与阅片要点
- 阅片时注意肿瘤中心位置是否靠近十二指肠、是否以实性为主,并结合动脉期和延迟期CT值协助鉴别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine useful contrast-enhanced computed tomography (CE-CT) features in differentiating duodenal gastrointestinal stromal tumors (duodenal GISTs) from hypervascular pancreatic neuroendocrine tumors in the pancreatic head (pancreatic head NETs).
METHODS: Seventeen patients with pathologically confirmed duodenal GISTs and 25 with pancreatic NETs underwent preoperative CE-CT. CT image analysis included tumor size, morphology, and contrast enhancement. Receiver operating characteristic curves were performed, and cutoff values were calculated to determine CT findings with high sensitivity and specificity.
RESULTS: CT imaging showed duodenal GISTs with higher frequencies of tumor central location close to the duodenum and a predominantly solid tumor type when compared with pancreatic head NETs (p < 0.05 for both). Duodenal GISTs were larger than pancreatic head NETs (3.3 ± 0.9 cm vs. 2.5 ± 1.1 cm, p = 0.03). Duodenal GISTs had significantly lower CT attenuation values (112.9 ± 17.9HU vs. 137.4 ± 32.1HU, p < 0.01) at the arterial phase and higher CT attenuation values at the delayed phase (94.3 ± 7.9HU vs. 84.9 ± 10.4HU, p < 0.01) when compared with pancreatic head NETs. A CT attenuation value of ≤ 135 HU at the arterial phase (30 s) was 76% sensitive, 94.1% specific, and 83.3% accurate for the diagnosis of duodenal GISTs, while a CT attenuation value of ≥ 89.5 HU at the delayed phase (120 s) was 93.3% sensitive, 81.8% specific, and 76.2% accurate for the diagnosis of duodenal GISTs.
CONCLUSION: Tumor central location, size, texture, and contrast enhancement are valuable characteristics for the differentiation between duodenal GISTs and hypervascular pancreatic head NETs during preoperative examination.
引用
- Ren S, Chen X, Wang J, et al. Differentiation of duodenal gastrointestinal stromal tumors from hypervascular pancreatic neuroendocrine tumors in the pancreatic head using contrast-enhanced computed tomography. Abdom Radiol (NY). 2019. PMID: 30293109. doi:10.1007/s00261-018-1803-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。