细胞外对比剂增强MRI采用伪黄金角径向采集与钆塞酸二钠增强MRI诊断肝细胞癌的个体内比较:基于LI-RADS
前瞻性研究纳入15例患者18个肝细胞癌,个体内比较伪黄金角径向采集的细胞外对比剂增强多期肝脏MRI与钆塞酸二钠增强MRI的图像质量和肝细胞癌诊断。动脉期主观图像质量无差异,伪影仅见于钆塞酸二钠增强MRI;细胞外对比剂增强MRI对动脉期高强化和包膜的显示更敏感,图像质量可接受。
要点
- 伪黄金角径向采集可用于自由呼吸多期动态肝脏MRI,图像质量可接受。
- 细胞外对比剂增强MRI较钆塞酸二钠增强MRI更敏感地显示肝细胞癌动脉期高强化。
- 包膜在细胞外对比剂增强MRI上显示更多(15个 vs 6个肝细胞癌)。
核心结论
- 采用伪黄金角径向采集的自由呼吸细胞外对比剂增强多期肝脏MRI在检测肝细胞癌动脉期高强化方面较传统钆塞酸二钠增强MRI更敏感,且图像质量可接受。
研究设计与样本
- 前瞻性研究,纳入15例患者共18个肝细胞癌,均行笛卡尔采集的钆塞酸二钠增强MRI和伪黄金角径向采集的细胞外对比剂增强MRI(注射后自由呼吸连续采集64秒,生成6幅图像),由两名阅片者评估。
关键影像表现/征象
- 动脉期主观图像质量分析在两种MRI间无差异(p > 0.05)。
- 重影伪影仅见于钆塞酸二钠增强MRI(N = 3)。
- 6个肝细胞癌在两种MRI的动脉期或门静脉期信号强度不同,其中5个在细胞外对比剂增强MRI上显示动脉期高强化而钆塞酸二钠增强MRI上未显示。
- 包膜在细胞外对比剂增强MRI上见于15个肝细胞癌,在钆塞酸二钠增强MRI上见于6个肝细胞癌。
诊断标准与关键数值
- 细胞外对比剂增强MRI将5个和1个肝细胞癌分别归为LR-5和LR-4,钆塞酸二钠增强MRI将对应病灶归为LR-4和LR-3。
临床应用与阅片要点
- 伪黄金角径向采集可用于自由呼吸多期动态肝脏MRI,有助于减少运动伪影。
- 采用伪黄金角径向采集可提高肝细胞癌动脉期强化的检出。
- 阅片时注意钆塞酸二钠增强MRI上可见重影伪影(本组N = 3)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the usefulness of extracellular contrast agent (ECA)-enhanced multiphasic liver magnetic resonance imaging (MRI) using a pseudo-golden-angle radial acquisition scheme by intra-individual comparison with gadoxetic acid-MRI (EOB-MRI) with regard to image quality and the diagnosis of hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: This prospective study enrolled 15 patients with 18 HCCs who underwent EOB-MRI using a Cartesian approach and ECA-MRI using the pseudo-golden-angle radial acquisition scheme (free-breathing continuous data acquisition for 64 s following ECA injection, generating six images). Two reviewers evaluated the arterial and portal phases of each MRI for artifacts, organ sharpness, and conspicuity of intrahepatic vessels and the hepatic tumors. A Liver Imaging Reporting and Data System category was also assigned to each lesion.
RESULTS: There were no differences in the subjective image quality analysis between the arterial phases of two MRIs (p > 0.05). However, ghosting artifact was seen only in EOB-MRI (N = 3). Six HCCs showed different signal intensities in the arterial phase or portal phase between the two MRIs; five HCCs showed arterial hyperenhancement on ECA-MRI, but not on EOB-MRI. The capsule was observed in 15 HCCs on ECA-MRI and 6 HCCs on EOB-MRI. Five and one HCC were assigned as LR-5 and LR-4 with ECA-MRI and LR-4 and LR-3 with EOB-MRI, respectively.
CONCLUSION: Free-breathing ECA-enhanced multiphasic liver MRI using a pseudo-golden-angle radial acquisition was more sensitive in detecting arterial hyperenhancement of HCC than conventional EOB-MRI, and the image quality was acceptable.
KEY POINTS: • The pseudo-golden-angle radial acquisition scheme can be applied to perform free-breathing multiphasic dynamic liver MRI. • Adopting the pseudo-golden-angle radial acquisition scheme can improve the detection of arterial enhancement of HCC. • The pseudo-golden-angle radial acquisition scheme enables motion-free liver MRI.
引用
- Kim YC, Min JH, Kim YK, et al. Intra-individual comparison of gadolinium-enhanced MRI using pseudo-golden-angle radial acquisition with gadoxetic acid-enhanced MRI for diagnosis of HCCs using LI-RADS. Eur Radiol. 2018. PMID: 30324388. doi:10.1007/s00330-018-5771-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。