模拟腹部CT滤波反投影技术剂量降低对肝脏病灶检测与表征的影响
回顾性纳入39例患者(19例有转移瘤、20例无),模拟100%、75%、50%、25%四档辐射剂量,5名阅片者标记肝脏病灶并以5级Likert量表评定恶性概率。JAFROC分析显示DL75对转移瘤检测与表征非劣于DL100,但DL75良性病灶及假阳性定位评为「可疑恶性」的数量显著增多;结论为辐射剂量可降低25%而不负面影响乏血供肝转移瘤诊断,但DL75下良性病灶表征受损,可能致不必要的随访。
要点
- 模拟剂量降至75%时,乏血供肝转移瘤的检测与表征非劣于100%参考剂量。
- DL75下良性病灶及假阳性定位被评为「可疑恶性」的数量显著高于DL100。
- 图像噪声增加对小结节检测的影响程度不能仅用CNR下降解释。
核心结论
- 辐射剂量可降低25%而不负面影响乏血供肝转移瘤的诊断。
- DL75下良性病灶表征受损,可能导致不必要的随访检查。
- 图像噪声增加似乎影响小结节检测,其程度不能仅由CNR降低解释。
研究设计与样本
- 回顾性选取39例患者,其中19例有肝转移瘤、20例无肝转移瘤。
- 模拟100%(参考水平)、75%、50%、25%四档辐射剂量水平。
- 5名阅片者标记肝脏病灶,并以5级Likert量表评定恶性概率。
- 采用jackknife自由响应ROC(JAFROC)方法进行非劣性分析,并直接比较检出率与评级。
诊断标准与关键数值
- 以5级Likert量表评定病灶恶性概率。
- JAFROC分析显示DL75对转移瘤的检测与表征非劣于DL100。
- DL75下良性病灶及假阳性定位评为「可疑恶性」的数量显著高于DL100。
临床应用与阅片要点
- 腹部CT辐射剂量可降低25%而不负面影响乏血供肝转移瘤诊断(原文结论)。
- DL75下良性病灶表征受损,可能致不必要的随访检查(原文结论)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Previous studies have shown the possibility to reduce radiation dose in abdominal CT by 25-50% without negatively affecting detection of liver lesions. How radiation dose reduction affects characterization of liver metastases is not as well known. The objective of this study was to investigate how different levels of simulated dose reduction affect the detection and characterization of liver lesions, primarily hypovascular metastases. A secondary objective was to analyze the relationship between the lesion size and contrast-to-noise ratio (CNR) and the detection rate.
MATERIALS AND METHODS: Thirty-nine patients (19 with metastases and 20 without) were retrospectively selected. The following radiation dose levels (DLs) were simulated: 100% (reference level), 75%, 50%, and 25%. Five readers were asked to mark liver lesions and rate the probability of malignancy on a 5-grade Likert scale. Noninferiority analysis using the jackknife free-response ROC (JAFROC) method was performed as well as direct comparison of detection rates and grades.
RESULTS: JAFROC analysis showed noninferior detection and characterization of metastases at DL75 as compared with DL100. However, the number of benign lesions and false-positive localizations rated as "suspected malignancy" was significantly higher at DL75.
CONCLUSION: Radiation dose can be reduced by 25% without negatively affecting diagnosis of hypovascular liver metastases. Characterization of benign lesions, however, is impaired at DL75, which may lead to unnecessary follow-up examinations. Finally, increased image noise seems to affect the detection of small lesions to a degree that cannot be explained solely by the reduction in CNR.
引用
- Fält T, Söderberg M, Hörberg L, et al. Simulated Dose Reduction for Abdominal CT With Filtered Back Projection Technique: Effect on Liver Lesion Detection and Characterization. AJR Am J Roentgenol. 2018. PMID: 30299999. doi:10.2214/AJR.17.19441
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。