文献速递腹部MR

扩散峰度成像在肝功能评估中的应用:其作为肝功能有效预测指标的潜力

Diffusion kurtosis imaging in the assessment of liver function: Its potential as an effective predictor of liver function.
PubMed 文献 · Br J Radiol · 2018-11-01

本研究纳入79例疑似肝胆疾病患者和15例无肝病对照,采用3.0 T磁共振行屏气扩散峰度成像(DKI),分析平均峰度值与Child-Pugh评分、ALBI评分及ICG-R15的相关性。平均峰度值与Child-Pugh评分(ρ=0.3992,p<0.0001)及ICG-R15(ρ=0.5972,p=0.00114)相关,与ALBI评分相关性最差(ρ=0.3395,p=0.0008)。作者结论认为DKI平均峰度值可定量评估与Child-Pugh评分和ICG-R15相关的肝功能,屏气DKI分析可用于替代实验室检查判断肝功能。

要点

  • 平均峰度值与Child-Pugh评分相关(ρ=0.3992,p<0.0001)。
  • 平均峰度值与ICG-R15相关(ρ=0.5972,p=0.00114)。
  • 平均峰度值与ALBI评分相关性最差(ρ=0.3395,p=0.0008)。

核心结论

  • DKI分析获得的平均峰度值可定量评估与Child-Pugh评分和ICG-R15值相关的肝功能;采用屏气技术的DKI分析可用于替代实验室检查判断肝功能。

研究设计与样本

  • 研究纳入疑似肝胆疾病患者79例和无肝病对照组15例,使用3.0 T磁共振行非高斯扩散加权成像(DKI);其中17例患者进行了ICG-R15检测;采用Spearman秩相关评估平均峰度值与Child-Pugh评分、ALBI评分及ICG-R15值的相关性,并评估表观扩散系数与这些指标的相关性。

诊断标准与关键数值

  • 平均峰度值与Child-Pugh评分的Spearman秩相关系数ρ=0.3992,p<0.0001。
  • 平均峰度值与ICG-R15值的Spearman秩相关系数ρ=0.5972,p=0.00114。
  • 平均峰度值与ALBI评分的Spearman秩相关系数ρ=0.3395,p=0.0008。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES:: We aimed to determine whether diffusion kurtosis imaging (DKI) analysis with the breath-hold technique can replace liver function results obtained from laboratory tests.

METHODS:: Patients (n = 79) suspected of having a hepatobiliary disease, and control group without liver diseases (n = 15) were examined with non-Gaussian diffusion-weighted imaging using a 3.0 T magnetic resonance imaging unit. Based on the findings of DKI, various blood serum parameters, including the indocyanine green (ICG) retention rate 15 min after an intravenous injection of ICG (ICG-R15) and mean kurtosis values and Child-Pugh and albumin-bilirubin (ALBI) scores, were calculated. In total, 17 patients were tested using ICG-R15. For evaluating liver function, correlations between the mean kurtosis value and the Child-Pugh score, ALBI score, and ICG-R15 value as indicators of liver function obtained from blood data were assessed using Spearman's rank correlation. In apparent diffusion coefficient as well, we assessed correlations with these indicators.

RESULTS:: The mean kurtosis value correlated with the Child-Pugh score (Spearman's rank-correlation coefficient, ρ = 0.3992; p < 0.0001). Moreover, the mean kurtosis value revealed a correlation with the ICG-R15 value (Spearman's rank-correlation coefficient, ρ = 0.5972; p = 0.00114). The correlation between the mean kurtosis value and the ALBI score was the poorest among these (Spearman's rank-correlation coefficient, ρ = 0.3395; p = 0.0008).

CONCLUSION:: Liver function correlating with the Child-Pugh score and ICG-R15 value can be quantitatively estimated using the mean kurtosis value obtained from DKI analysis. DKI analysis with the breath-hold technique can be used to determine liver function instead of performing laboratory tests.

ADVANCES IN KNOWLEDGE:: Previous studies have not evaluated liver function in vivo using DKI.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Yoshimaru D, Takatsu Y, Suzuki Y, et al. Diffusion kurtosis imaging in the assessment of liver function: Its potential as an effective predictor of liver function. Br J Radiol. 2018. PMID: 30358410. doi:10.1259/bjr.20170608

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。