文献速递腹部泌尿生殖MR

克罗恩病小肠并发症的术前评估:弥散加权与对比增强MR成像的比较

Preoperative evaluation of small bowel complications in Crohn's disease: comparison of diffusion-weighted and contrast-enhanced MR imaging.
PubMed 文献 · Eur Radiol · 2018-10-09

本研究纳入38例因克罗恩病并发症接受手术并有术前MR小肠造影的患者,由一名初级和一名高级腹部放射科医生盲法独立分析两套序列组合(T2加权+弥散加权 vs T2加权+对比增强)对瘘管、狭窄和脓肿的检出效能,以术中和病理 findings 为标准。高级医生两套序列敏感度80%-100% vs 88%-100%、特异度56%-70% vs 53%-93%,无显著差异;初级医生对比增强序列敏感度64%-88%、特异度17%-40%,优于弥散加权序列的53%-63%和0%-25%(P=0.001和0.007)。结论:对高级医生,弥散加权MR小肠造影与对比增强MR小肠造影敏感度相似;对初级医生,对比增强MR小肠造影结果最佳。

要点

  • 高级医生用弥散加权序列与对比增强序列检出克罗恩病并发症的敏感度相似。
  • 初级医生使用对比增强序列的敏感度和特异度均优于弥散加权序列。
  • 弥散加权序列判读克罗恩病并发症需要一定经验。

核心结论

  • 对高级放射科医生,弥散加权MR小肠造影检测克罗恩病并发症的敏感度与对比增强MR小肠造影相似;对初级放射科医生,对比增强MR小肠造影结果最佳。

研究设计与样本

  • 回顾性纳入2011至2016年因克罗恩病并发症接受手术且有术前MR小肠造影的38例患者,由一名初级和一名高级腹部放射科医生盲法独立分析两套序列组合,以术中和病理 findings 为标准参考。

关键影像表现/征象

  • 共发现48处瘘管、43处狭窄和11处脓肿。
  • 高级医生组:瘘管、狭窄和脓肿检出的敏感度第一套序列为80%至100%,第二套序列为88%至100%。
  • 高级医生组:特异度第一套序列为56%至70%,第二套序列为53%至93%,两套序列间无显著差异(P=0.342至0.429)。
  • 初级医生组:敏感度第一套序列为53%至63%,第二套序列为64%至88%。
  • 初级医生组:特异度第一套序列为0%至25%,第二套序列为17%至40%(P分别为0.001和0.007)。

诊断标准与关键数值

  • 第一套序列组合为T2加权成像、稳态序列和弥散加权MR小肠造影。
  • 第二套序列组合为T2加权成像、True-FISP和对比增强MR小肠造影。
  • 以术中和病理 findings 作为标准参考。

临床应用与阅片要点

  • 高级放射科医生判读时,弥散加权MR小肠造影对克罗恩病并发症的诊断能力与对比增强MR成像相似。
  • 高级放射科医生诊断克罗恩病并发症时,可免除钆螯合物注射。
  • 弥散加权MR小肠造影判读克罗恩病并发症需要一定经验。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the accuracy of MR enterography (MRE) using combined T2-weighted and contrast-enhanced (CE) sequences with that of combined T2- and diffusion-weighted (DW) sequences for the detection of complex enteric Crohn's disease (CD).

MATERIALS: Thirty-eight patients who underwent surgery for CD complications and preoperative MRE from 2011 to 2016 were included. MRE examinations were blindly analyzed independently by one junior and one senior abdominal radiologist for the presence of fistula, stenosis and abscesses. During a first reading session, T2-weighted images (WI), steady-state sequences and DW-MRE were reviewed (set 1). During a separate distant session, T2-WI, True-FISP and CE-MRE were reviewed (set 2). Performance of each reader was evaluated by comparison with the standard of reference established using intraoperative and pathological findings.

RESULTS: Forty-eight fistulas, 43 stenoses and 11 abscesses were found. For the senior radiologist, sensitivity for the detection of fistula, stenosis and abscess ranged from 80% to 100% for set 1 and 88% to 100% for set 2 and specificity ranged from 56% to 70% for set 1 and 53% to 93% for set 2, with no significant difference between the sets (p = 0.342-0.429). For the junior radiologist, sensitivity ranged from 53% to 63% for set 1 and 64% to 88% for set 2 and specificity ranged from 0% to 25% for set 1 and 17% to 40% for set 2 (p = 0.001 and 0.007, respectively).

CONCLUSION: For a senior radiologist, DW-MRE has similar sensitivity as CE-MRE for the detection of CD complications. For a junior radiologist, CE-MRE yields the best results compared with DW-MRE.

KEY POINTS: • For experienced readers, DWI has similar diagnostic capability as contrast-enhanced MR imaging for the diagnosis of Crohn's disease complications. • For senior radiologists, gadolinium chelate injection could be waived for the diagnosis of Crohn's disease complications. • The interpretation of DWI for Crohn's disease complications requires some experience.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Barat M, Hoeffel C, Bouquot M, et al. Preoperative evaluation of small bowel complications in Crohn's disease: comparison of diffusion-weighted and contrast-enhanced MR imaging. Eur Radiol. 2018. PMID: 30302591. doi:10.1007/s00330-018-5734-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。