标准屏气、自由呼吸与压缩感知二维梯度回波磁共振弹性成像评估肝脏硬度的比较

Comparison of Standard Breath-Held, Free-Breathing, and Compressed Sensing 2D Gradient-Recalled Echo MR Elastography Techniques for Evaluating Liver Stiffness.
PubMed 文献 · AJR Am J Roentgenol · 2018-10-09

研究纳入25名成年志愿者(20名无肝病、5名有肝病),比较屏气、自由呼吸及压缩感知加速因子1.5、2、3共五种二维梯度回波磁共振弹性成像技术测量肝脏硬度。三种读者中,读者1和3各技术间平均肝硬度无显著差异(p>0.05),读者2自由呼吸技术测值较高致显著差异(p=0.02);各读者技术间绝对一致性极佳(ICC均>0.940),偏差小。自由呼吸和压缩感知加速技术结果与常规屏气技术相似,仅轻微偏差,可能适用于屏气能力受限的儿童和成人患者。

要点

  • 自由呼吸与压缩感知加速2D GRE MRE测肝硬度与屏气技术结果相似,仅轻微偏差。
  • 各读者技术间绝对一致性极佳,ICC均>0.940。
  • 自由呼吸和压缩感知技术可能适用于屏气能力受限的儿童和成人患者。

核心结论

  • 自由呼吸和压缩感知加速2D GRE MRE技术与常规屏气技术结果相似,仅轻微偏差,可能适用于屏气能力受限的儿童和成人患者。

研究设计与样本

  • 研究纳入25名成年志愿者(20名无肝病、5名有肝病),每人均接受五种2D GRE MRE技术检查:屏气、自由呼吸及压缩感知加速因子1.5、2、3。
  • 每种技术于肝中部获取4幅轴位图像,由三名盲法读者使用带95%置信图的弹性图测量肝硬度(千帕)。
  • 采用重复测量方差分析比较各技术肝硬度,以单次测量组内相关系数(ICC)评估各读者技术间绝对一致性,以屏气MRE为参考用Bland-Altman分析评估技术间偏差。

诊断标准与关键数值

  • 个体受试者平均肝硬度范围为1.35至5.25 kPa。
  • 读者1和3各MRE技术间平均肝硬度无显著差异(p>0.05);读者2因自由呼吸MRE测值较高出现显著差异(p=0.02)。
  • 各读者技术间绝对一致性极佳(所有ICC均>0.940)。
  • 技术间偏差:读者1为-0.102至0.089 kPa,读者2为-0.119至0.121 kPa,读者3为-0.074至0.085 kPa。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of our study was to compare standard breath-held, free-breathing, and compressed sensing (CS) accelerated 2D gradient-recalled echo (GRE) MR elastography (MRE) techniques for measuring liver stiffness.

SUBJECTS AND METHODS: Twenty-five adult volunteers (20 without liver disease and five with liver disease) underwent MRE with five different 2D GRE techniques: breath-held; free-breathing; and CS with acceleration factors of 1.5, 2, and 3. Four axial images were obtained through the mid liver with each technique, and liver stiffness measurements (in kilopascals) were made by three blinded readers using elastograms with 95% confidence maps. Liver stiffness measurements were compared between techniques using repeated-measures ANOVA. Absolute agreement between techniques was evaluated for each reader using single-measure intraclass correlation coefficients (ICCs). Bland-Altman analyses were performed to assess bias between techniques using breath-held MRE as the reference.

RESULTS: Individual subject mean liver stiffness values ranged from 1.35 to 5.25 kPa for the population. There was no significant difference in mean liver stiffness values between MRE techniques for readers 1 and 3 (p > 0.05). A significant difference (p = 0.02) due to higher stiffness measurements using free-breathing MRE was observed for reader 2. There was excellent absolute agreement between MRE techniques for each reader (all ICCs > 0.940). Bias between techniques ranged from -0.102 to 0.089 kPa for reader 1, -0.119 to 0.121 kPa for reader 2, and -0.074 to 0.085 kPa for reader 3.

CONCLUSION: Free-breathing and CS accelerated 2D GRE MRE techniques yield similar results to the conventional breath-held technique with only slight bias and may be useful in pediatric and adult patients with limited ability to breath-hold.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。