微泡尺寸与脉冲幅度对对比增强诊断超声所致肝细胞损伤的影响

Influence of Microbubble Size and Pulse Amplitude on Hepatocyte Injury Induced by Contrast-Enhanced Diagnostic Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2018-10-23

本研究评估低剂量输注和低输出条件下间歇暴露的效应以确定阈值,并测试含较大微泡的悬液。肝细胞损伤随微泡平均直径增大而阈值降低,较大微泡增强效应支持空化微血管损伤的双标准模型。总体而言,对比增强诊断超声在肝脏诱导组织损伤的潜力似乎明显低于其他组织已报告的潜力。

要点

  • 正常微泡在临床相关输注剂量下肝细胞损伤计数增加,但在20 µL/kg/min以上趋于平稳。
  • 损伤证据从30分钟到4小时随时间下降,24小时时未见到损伤。
  • 正常、中等和大型微泡的原位机械指数阈值分别为1.7、1.3和1.2。

核心结论

  • 对比增强诊断超声在肝脏诱导组织损伤的潜力似乎明显低于其他组织已报告的潜力,表明在正常肝脏中使用推荐参数时具有令人满意的安全性特征。

研究设计与样本

  • 研究采用相控阵探头(GE Vivid 7 Dimension,GE Vingmed Ultrasound,Horten,Norway),以1.6 MHz、1秒间歇帧触发暴露10分钟,输注平均微泡直径正常(1.8 µm)、中等(3.1 µm)和大型(5.3 µm)的微泡悬液;生物效应终点为冷冻切片中伊文思蓝染色的肝细胞计数。

诊断标准与关键数值

  • 正常微泡:临床相关输注剂量下肝细胞损伤计数增加,但在20 µL/kg/min以上趋于平稳。
  • 损伤证据从30分钟到4小时随时间下降,24小时时未见到损伤。
  • 以峰值负压幅度除以频率平方根(原位机械指数)表示的暴露阈值:正常微泡1.7,中等微泡1.3,大型微泡1.2。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Recent research has found that contrast-enhanced diagnostic ultrasound (CEDUS) has the potential to induce localized injury in the liver, with clearly observable effects for contrast agent doses higher than the recommended dose and maximal mechanical index values. This study was undertaken to assess effects with intermittent exposure at lower contrast doses of infusion and at reduced output to determine thresholds. In addition, microbubble (MB) suspensions with enhanced content of larger MBs were tested. Exposure from a phased array probe (GE Vivid 7 Dimension, GE Vingmed Ultrasound, Horten, Norway) was applied at 1.6 MHz and 1-s intermittent frame trigger for 10 min with infusion of MB suspension with normal (1.8 µm), medium (3.1 µm) and large (5.3 µm) mean MB diameters. The bio-effect endpoint was the count of hepatocytes stained with Evans blue dye in frozen sections. For the normal MBs, the count increased for clinically relevant infusion dosages, but leveled off above 20 µL/kg/min. The evidence of injury declined with time from 30 min to 4 h and was lacking at 24 h. The exposure thresholds in terms of peak rarefactional pressure amplitude, divided by the square root of frequency (in situ mechanical index) were 1.7, 1.3 and 1.2 for the normal-, medium- and large-sized MB suspensions. The enhanced efficacy for larger MBs lends support to the two-criterion model for cavitational microvascular injury during CEDUS. Overall, CEDUS in liver appears to have markedly less potential for induction of tissue injury than has been reported in other tissues, which indicates a satisfactory safety profile for CEDUS using recommended parameters in normal liver.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。