文献速递腹部泌尿生殖技术与安全US

数据解析对超声造影检查的影响

Influence of Data Parsing on Contrast Enhanced Ultrasound Exams.
PubMed 文献 · Acad Radiol · 2018-10-10

本研究纳入40例连续超声造影检查,比较全动态回放、操作超声技师选帧及每10、30、60秒系统存帧对医生诊断与信心的影响。结果显示技师选帧与全动态回放诊断表现及信心无显著差异(p > 0.42),10秒间隔诊断表现无显著变化但信心下降,30-60秒间隔诊断表现与信心均显著降低(p < 0.045)。

要点

  • 技师选帧与全动态回放诊断表现及信心无显著差异(p > 0.42)。
  • 每10秒存帧诊断表现与全动态回放无显著差异(p > 0.18),但医生信心下降。
  • 每30-60秒存帧诊断表现与信心均较全动态回放显著降低(p < 0.045)。

核心结论

  • 操作超声技师选帧可提供与全动态回放同等的诊断价值,避免全动态回放所需阅片时间和数据存储成本;按时间点解析会降低医生信心和诊断表现。

研究设计与样本

  • 研究纳入40例连续超声造影检查,包括10例不确定肝脏病变、10例不确定肾脏病变、10例肾细胞癌消融后随访和10例肝细胞癌化疗栓塞后随访。

诊断标准与关键数值

  • 全动态回放与技师选帧比较,诊断表现指标及阅片信心差异均无统计学意义(p > 0.42)。
  • 每10秒间隔存帧与全动态回放比较,所有应用诊断表现无统计学显著变化(p > 0.18),但阅片信心下降。
  • 每30-60秒间隔存帧与全动态回放比较,诊断表现和阅片信心均显著降低(p < 0.045)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To explore the influence of data parsing (either selection of frames at set time intervals or by an experienced sonographer) of contrast-enhanced ultrasound (CEUS) exams on physician diagnoses and confidence levels.

MATERIALS AND METHODS: Forty consecutive CEUS exams consisting of 10 cases each of indeterminate liver lesions, indeterminate renal lesions, renal cell carcinoma postablation follow-up, and hepatocellular carcinoma postchemoembolization follow-up were selected for analysis. Exams were parsed into sets consisting of five images selected by the performing sonographer and sets containing systematically stored frames every 10, 30, and 60 seconds. Three blinded physicians then reviewed the cine loop and each set of images in randomized order and provided a diagnosis and confidence level.

RESULTS: For all clinical applications investigated, no statistically significant differences in diagnostic performance measures or reader confidence were observed between review of the entire cine loop and images selected by the performing sonographer (p > 0.42). Diagnostic performance at 10-second intervals did not show statically significant changes compared to the full cine loop review for all applications (p > 0.18), although reader confidence decreased. At 30-60-second intervals, both diagnostic performance and reader confidence showed statistically significant reduction compared to review of the full cine loop (p < 0.045).

CONCLUSIONS: Transfer and review of large cine loops from CEUS exams represent a potential barrier to adoption within the United States workflows. This study demonstrates that images selected by a performing trained sonographer may provide the same value without the review time and data storage costs needed for full cine loop review. Parsing by time points reduced reader confidence and diagnostic performance.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Needleman L, Liu JB, et al. Influence of Data Parsing on Contrast Enhanced Ultrasound Exams. Acad Radiol. 2018. PMID: 30316706. doi:10.1016/j.acra.2018.09.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。