文献速递心血管泌尿生殖CTMR

显示色彩尺度对心脏CT和前列腺表观扩散系数评估中诊断性能与阅片者一致性的影响

Display colour scale effects on diagnostic performance and reader agreement in cardiac CT and prostate apparent diffusion coefficient assessment.
PubMed 文献 · Clin Radiol · 2018-10-15

研究纳入12名临床医生解读210例心肌CT灌注(CTP)检查和9名临床医生解读165例MRI前列腺ADC图像,每人在灰度、热铁和彩虹三种色彩尺度下分别阅片并对肿瘤或缺血存在置信度评分0-100。CTP检测中灰度AUC最高(0.67±0.02),彩虹最低(0.56±0.02),热铁居中(0.61±0.03);缺血透壁程度分类中灰度在25-50%类别观察者间一致性最高;前列腺肿瘤检测中彩虹和灰度有优于热铁的小趋势,所选最低ADC值和像素定位在各色彩尺度间相似。结论提示色彩可视化对CTP和ADC性能有可测量影响,需进一步研究确定诊断任务中的效应大小。

要点

  • CTP缺血检测:灰度AUC 0.67±0.02 vs 彩虹0.56±0.02,热铁居中0.61±0.03。
  • 缺血透壁程度25-50%类别,灰度观察者间一致性最高。
  • 前列腺肿瘤检测:彩虹和灰度有优于热铁的小趋势,最低ADC值及定位各尺度相似。

核心结论

  • 色彩可视化对CTP和ADC诊断性能有可测量影响,需进一步研究确定诊断任务中的效应大小。

研究设计与样本

  • 12名临床医生解读210例心肌CT灌注(CTP)检查,9名临床医生解读165例MRI前列腺ADC图像;每人分三次分别用灰度、热铁、彩虹尺度阅同一图像集,置信度0-100,以ROC曲线下面积(AUC)为性能指标。

诊断标准与关键数值

  • CTP缺血检测AUC:灰度0.67±0.02(标准误),热铁0.61±0.03,彩虹0.56±0.02,灰度较彩虹高至多0.10。
  • 缺血透壁程度分类(评分>50的病例):观察者间一致性在25-50%类别以灰度最高。
  • 前列腺肿瘤检测:彩虹和灰度有优于热铁的小趋势;所选最低ADC值和像素定位在各色彩尺度间相似。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需进一步研究以确定该效应在诊断任务中的大小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the effect of colour scale choice on diagnostic performance in the interpretation of medical images.

MATERIALS AND METHODS: Twelve clinicians interpreted 210 myocardial computed tomography (CT) perfusion (CTP) examinations, and nine clinicians interpreted 165 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) prostate images. In three separate sessions, each participant read the same image set using greyscale, hot-iron, and rainbow scales, respectively. Participants scored their level of confidence for tumour presence in the ADC study, and for ischaemia in the CTP study, from 0 to 100. The area under the receiver operating characteristic (ROC) curve (AUC) was used as the performance metric. For cases that scored >50, CTP readers' agreement on the ischaemic transmural extent was analysed, and ADC map readers' selected values and coordinates for the lowest ADC within the detected tumour were compared across different colour scales.

RESULTS: For CTP detection, the AUC was up to 0.10 higher with greyscale, 0.67±0.02 (standard error), compared to rainbow, 0.56±0.02, and detection with hot-iron was in between (0.61±0.03). For ischaemic transmural lesion categorisation, observed inter-reader agreement was highest with greyscale for category 25-50%. There is a small tendency for rainbow and greyscale to outperform hot-iron in the detection of prostate tumours. The selected lowest ADC value and pixel localisation was similar with all colour scales.

CONCLUSIONS: The present findings suggest that colour visualisation has a measurable effect on CTP and ADC performance. Further investigation is necessary to determine the magnitude of the effect in diagnostic tasks.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zabala-Travers S, Gallas BD, Busoni S, et al. Display colour scale effects on diagnostic performance and reader agreement in cardiac CT and prostate apparent diffusion coefficient assessment. Clin Radiol. 2018. PMID: 30336942. doi:10.1016/j.crad.2018.08.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。