基于快速计算分析的无创CT血流动力学评估冠状动脉病灶:与血流储备分数的比较
本研究对63例胸痛且冠心病验前概率中等(20-90%)的患者行CTCA和有创FFR测量,用自研自动化软件基于三维CTCA数据计算虚拟功能评估指数(vFAI),共分析74支血管;vFAI与FFR强相关(R=0.93,p<0.001),识别FFR≤0.8的最佳vFAI截断值为≤0.82(95%CI 0.81-0.88)。
要点
- vFAI与FFR强相关(R=0.93,p<0.001),Bland-Altman分析示两者一致性很好。
- 识别FFR≤0.8的最佳vFAI截断值为≤0.82(95%CI 0.81-0.88)。
- vFAI可能有效区分血流动力学显著与非显著病灶。
核心结论
- vFAI可有效基于三维CTCA数据集通过计算流体动力学得出,在狭窄程度>30%且≤90%的患者中与FFR对照表现良好,可能有效区分血流动力学显著与非显著病灶。
研究设计与样本
- 63例有胸痛症状且冠心病验前概率中等(20-90%)的患者接受CTCA及有创冠状动脉造影FFR测量,共分析74支血管;行冠状动脉血管三维重建后采用有限元法进行血流模拟并计算vFAI,CTCA平均处理时间25(±10)分钟。
诊断标准与关键数值
- vFAI与FFR强相关(R=0.93,p<0.001),Bland-Altman分析示两者一致性很好,两种方法测量平均差值为0.03(SD=0.033),提示vFAI对FFR存在小幅系统性高估;受试者工作特征曲线分析显示,识别FFR阈值≤0.8的最佳vFAI截断值为≤0.82(95%CI 0.81-0.88)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Application of computational fluid dynamics (CFD) to three-dimensional CTCA datasets has been shown to provide accurate assessment of the hemodynamic significance of a coronary lesion. We aim to test the feasibility of calculating a novel CTCA-based virtual functional assessment index (vFAI) of coronary stenoses > 30% and ≤ 90% by using an automated in-house-developed software and to evaluate its efficacy as compared to the invasively measured fractional flow reserve (FFR).
METHODS AND RESULTS: In 63 patients with chest pain symptoms and intermediate (20-90%) pre-test likelihood of coronary artery disease undergoing CTCA and invasive coronary angiography with FFR measurement, vFAI calculations were performed after 3D reconstruction of the coronary vessels and flow simulations using the finite element method. A total of 74 vessels were analyzed. Mean CTCA processing time was 25(± 10) min. There was a strong correlation between vFAI and FFR, (R = 0.93, p < 0.001) and a very good agreement between the two parameters by the Bland-Altman method of analysis. The mean difference of measurements from the two methods was 0.03 (SD = 0.033), indicating a small systematic overestimation of the FFR by vFAI. Using a receiver-operating characteristic curve analysis, the optimal vFAI cutoff value for identifying an FFR threshold of ≤ 0.8 was ≤ 0.82 (95% CI 0.81 to 0.88).
CONCLUSIONS: vFAI can be effectively derived from the application of computational fluid dynamics to three-dimensional CTCA datasets. In patients with coronary stenosis severity > 30% and ≤ 90%, vFAI performs well against FFR and may efficiently distinguish between hemodynamically significant from non-significant lesions.
KEY POINTS: Virtual functional assessment index (vFAI) can be effectively derived from 3D CTCA datasets. In patients with coronary stenoses severity > 30% and ≤ 90%, vFAI performs well against FFR. vFAI may efficiently distinguish between functionally significant from non-significant lesions.
引用
- Siogkas PK, Anagnostopoulos CD, Liga R, et al. Noninvasive CT-based hemodynamic assessment of coronary lesions derived from fast computational analysis: a comparison against fractional flow reserve. Eur Radiol. 2018. PMID: 30324382. doi:10.1007/s00330-018-5781-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。