两种超极化129Xe MRI通气量化流程的比较:信噪比的影响

A Comparison of Two Hyperpolarized 129Xe MRI Ventilation Quantification Pipelines: The Effect of Signal to Noise Ratio.
PubMed 文献 · Acad Radiol · 2018-09-27

该研究回顾性纳入29例受试者,比较线性分箱法与自适应K-means法在超极化129Xe MRI通气缺陷百分比(VDP)及其他通气簇分类上的一致性及对信噪比(SNR)降低的稳健性。两种方法在VDP量化上一致性良好,但低通气百分比(LVP)和中通气百分比(MVP)的一致性可变。作者建议稳健测定VDP所需SNR最低为6.6,而稳健量化通气簇需SNR达13.4。

要点

  • 线性分箱法与K-means法在VDP量化上一致性良好,偏差为+1.5%。
  • LVP和MVP的组间一致性中等,偏差分别为-5.7%和8.1%。
  • 作者建议稳健测定VDP的SNR最低值为6.6。

核心结论

  • 两种方法在量化VDP上一致性良好,但LVP和MVP的一致性可变;作者建议稳健测定VDP的SNR阈值至少为6.6,而稳健量化通气簇需SNR达13.4。

研究设计与样本

  • 回顾性研究,共纳入29例受试者(年龄38.4 ± 19.0岁),对每张129Xe通气图像生成7张信噪比递减的图像,共8组图像分别用线性分箱法和自适应K-means法独立分析。

关键影像表现/征象

  • 两种方法均将所有肺体素分类为VDP、低通气百分比(LVP)、中通气百分比(MVP)和高通气百分比(HVP)四个簇。
  • 当SNR降至约4以下时,两种方法报告的值均开始明显偏离原始图像。

诊断标准与关键数值

  • VDP的组间一致性界限为[+0.2%, +4.0%],线性分箱法相对于K-means法的偏差为+1.5%。
  • LVP、MVP和HVP的偏差分别为-5.7%、8.1%和-4.0%。
  • 要求VDP与原始图像计算值偏差≤1.8%时,线性分箱法的最小可耐受SNR为2.4 ± 1.0,K-means法为3.5 ± 1.5。
  • 作者建议稳健测定VDP的SNR阈值应高于3.5 ± 1.5最小值两个标准差,即最低SNR为6.6;稳健量化通气簇需SNR为13.4。

临床应用与阅片要点

  • 作者建议稳健测定VDP的SNR最低值为6.6,稳健量化通气簇需SNR达13.4。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE: Hyperpolarized 129Xe MRI enables quantitative evaluation of regional ventilation. To this end, multiple classifiers have been proposed to determine ventilation defect percentage (VDP) as well as other cluster populations. However, consensus has not yet been reached regarding which of these methods to deploy for multicenter clinical trials. Here, we compare two published classification techniques-linear-binning and adaptive K-means-to establish their limits of agreement and their robustness against reduced signal-to-noise ratio (SNR).

METHODS: A total of 29 subjects (age: 38.4 ± 19.0 years) were retrospectively identified for inter-method comparison. For each 129Xe ventilation image, 7 images with reduced SNR were generated with equal decrements relative to the native SNR. All 8 sets of images were then analyzed using both methods independently to classify all lung voxels into four clusters: VDP, low-, medium-, and high-ventilation-percentage (LVP, MVP and HVP). For each cluster, the percentage of the lung it comprised was compared between the two methods, as well as how these values persisted as SNR was degraded.

RESULTS: The limits of agreement for calculating VDP were [+0.2%, +4.0%] with a +1.5% bias for binning relative to K-means. However, the inter-method agreement for the other clusters was moderate, with biases of -5.7%, 8.1%, and -4.0% for LVP, MVP, and HVP, respectively. As SNR decreased below ∼4, both methods began reporting values that deviated substantially from the native image. By requiring VDP to remain within ≤1.8% of that calculated from the native image, the minimum tolerable SNR values were 2.4 ± 1.0 for the linear-binning, and 3.5 ± 1.5 for the K-means.

CONCLUSIONS: Both methods agree well in quantifying VDP, but agreement for LVP and MVP remains variable. We suggest a required SNR threshold be two standard deviations above the minimum value of 3.5 ± 1.5 for robust determination of VDP, suggesting a minimum SNR of 6.6. However, robust quantification of the ventilated clusters required an SNR of 13.4.