文献速递胸部CT

亚实性结节内「实性」成分的影像定义、显示及其与肺腺癌侵袭性的相关性:CT直方图与主观评价的比较

The "solid" component within subsolid nodules: imaging definition, display, and correlation with invasiveness of lung adenocarcinoma, a comparison of CT histograms and subjective evaluation.
PubMed 文献 · Eur Radiol · 2018-10-15

回顾性分析328例病理证实的表现为亚实性结节的肺腺癌,比较三种「实性」成分定义、三维CT直方图及10种中等窗设置对侵袭性的鉴别效能;-50 WL/2 WW的AUC大于其他9种中等窗设置及定义2,特异度82.5%、PPV 88.5%,高于CT直方图平行诊断和定义2,作者认为该窗设置是评估「实性」成分和鉴别侵袭性的最优方法。

要点

  • 定义2(纵隔窗可见)诊断准确率75.6%,高于另外两种定义(p<0.01)。
  • -50 WL/2 WW的AUC大于其他9种中等窗设置及定义2。
  • -50 WL/2 WW特异度82.5%、PPV 88.5%,高于CT直方图平行诊断和定义2。

核心结论

  • 使用-50 WL/2 WW是评估「实性」成分和鉴别侵袭性的最优方法,优于三维CT直方图和定义2,且便于常规临床评估。

研究设计与样本

  • 回顾性分析328例病理证实的表现为亚实性结节的肺腺癌,以病理为参考标准;生成三维CT直方图(11个CT衰减区间,-400至50 HU,每50 HU间隔),提出三种「实性」成分定义并设置10种中等窗设置。

关键影像表现/征象

  • 亚实性结节内「实性」成分的定义与显示方式影响对肺腺癌侵袭性的判断。
  • 采用AUC最大的5个CT衰减区间平行诊断(AUC≥0.797),敏感度78%、特异度73.7%。
  • 定义2(纵隔窗可见)诊断准确率75.6%,高于另外两种定义(p<0.01)。

诊断标准与关键数值

  • 5个CT衰减区间平行诊断:AUC≥0.797,敏感度78%,特异度73.7%。
  • 定义2(纵隔窗可见)诊断准确率75.6%。
  • -50 WL/2 WW:AUC大于其他9种中等窗设置及定义2,特异度82.5%,PPV 88.5%。

临床应用与阅片要点

  • 作者认为-50 WL/2 WW是评估「实性」成分和鉴别侵袭性的最优方法,优于三维CT直方图和定义2,且便于常规临床评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To validate three proposed definitions of the "solid" component of subsolid nodules, as compared to CT histograms and the use of different window settings, for discriminating the invasiveness of adenocarcinomas in a manner that facilitates routine clinical assessment.

METHODS: We retrospectively analyzed 328 pathologically confirmed lung adenocarcinomas, manifesting as subsolid nodules. Three-dimensional CT histograms were generated by setting 11 CT attenuation intervals from - 400 to 50 HU, at 50 HU intervals, and the voxel percentage within each CT attenuation interval was generated automatically. Three definitions of the "solid" component were proposed, and 10 medium window settings were set to evaluate the "solid" component. The diagnostic performance of the three definitions for identifying invasive adenocarcinoma was compared with that of CT histogram analysis and subjective evaluation with medium window settings.

RESULTS: A parallel diagnosis using five intervals with the largest AUC (AUC ≥ 0.797) demonstrated good differential diagnostic performance, with 78% sensitivity and 73.7% specificity. Definition 2 (visibility in the mediastinum window) yielded higher accuracy (75.6%) than the other two definitions (p < 0.01). A medium window setting of - 50 WL/2 WW gave a larger AUC than the other nine medium window settings as well as definition 2, with 82.5% specificity and 88.5% PPV, which was higher than those of parallel diagnosis with CT histogram and definition 2.

CONCLUSION: Using - 50 WL/2 WW is the optimum approach for evaluating the "solid" component and discriminating invasiveness, superior to using 3D CT histograms and definition 2, and convenient in routine clinical assessment.

KEY POINTS: • - 50 WL/2 WW gave a larger AUC than definition 2. • The specificity of - 50 WL/2 WW was higher than CT histograms. • - 50 WL/2 WW offers the best evaluation of the solid component.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tu W, Li Z, Wang Y, et al. The "solid" component within subsolid nodules: imaging definition, display, and correlation with invasiveness of lung adenocarcinoma, a comparison of CT histograms and subjective evaluation. Eur Radiol. 2018. PMID: 30324380. doi:10.1007/s00330-018-5778-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。