定量CT检测重度哮喘支气管热成形术后气道尺寸与气体潴留的变化
研究对17例重度哮喘患者支气管热成形术(BT)前后及术后两年内行配对吸呼气和吸气CT,并与11例保守治疗患者对照,用全自动软件定量气道壁厚、壁百分比及气体潴留指标。BT后第2–7级气道壁厚显著减少0.06 mm、壁百分比减少2.05%,吸气/呼气平均肺衰减比值(E/I MLA)和-950至-856 HU间相对容积变化(RVC856-950)分别显著降低12.65%和1.77%,对照组无显著变化。
要点
- BT后第2–7级气道壁厚减少0.06 mm(p=0.026)、壁百分比减少2.05%(p<0.001),管腔面积和总直径无显著变化。
- BT后E/I MLA降低12.65%、RVC856-950降低1.77%(均p<0.001),提示气体潴留改善。
- 对照组气道指标与气体潴留指标均无显著变化。
核心结论
- BT显著减轻重度哮喘患者的气道狭窄和气体潴留,可能反映气道平滑肌质量减少及神经支配改变的直接治疗效应;气体潴留减少提示对BT未直接处理的更外周气道也有影响。
研究设计与样本
- 配对吸呼气CT和吸气CT研究,17例重度哮喘患者BT前及术后至两年随访,另11例保守治疗重度哮喘患者对照,采用全自动软件定量气道指标和气体潴留。
关键影像表现/征象
- BT后第2–7级气道合并分析壁厚显著减少0.06 mm(p=0.026),壁百分比显著减少2.05%(p<0.001)。
- BT后管腔面积和总直径无显著变化(p=0.147,p=0.706)。
- BT后E/I MLA显著降低12.65%、RVC856-950显著降低1.77%(均p<0.001)。
- 对照组上述气道指标和气体潴留指标均无显著变化。
诊断标准与关键数值
- 气道指标由全自动软件计算,包括壁厚(WT)、壁百分比(WP)、管腔面积(LA)和总直径(TD)。
- 气体潴留以呼气与吸气平均肺衰减比值(E/I MLA)及呼气至吸气在-950至-856 HU间相对容积变化(RVC856-950)定量,按气道级别和肺叶分析。
临床应用与阅片要点
- 定量CT可用于BT术后随访,评估气道壁厚、壁百分比及气体潴留指标的变化。
- 分析气道指标时可按第2–7级气道合并分析,气体潴留可按气道级别和肺叶分别定量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Bronchial thermoplasty (BT) can be considered in the treatment of severe asthma to reduce airway smooth muscle mass and bronchoconstriction. We hypothesized that BT may thus have long-term effects on airway dimensions and air-trapping detectable by quantitative computed tomography (QCT).
METHODS: Paired in- and expiratory CT and inspiratory CT were acquired in 17 patients with severe asthma before and up to two years after bronchial thermoplasty and in 11 additional conservatively treated patients with serve asthma, respectively. A fully automatic software calculated the airways metrics for wall thickness (WT), wall percentage (WP), lumen area (LA) and total diameter (TD). Furthermore, lung air-trapping was quantified by determining the quotient of mean lung attenuation in expiration vs. inspiration (E/I MLA) and relative volume change in the Hounsfield interval -950 to -856 in expiration to inspiration (RVC856-950) in a generation- and lobe-based approach, respectively.
RESULTS: BT reduced WT for the combined analysis of the 2nd-7th airway generation significantly by 0.06 mm (p = 0.026) and WP by 2.05% (p < 0.001), whereas LA and TD did not change significantly (p = 0.147, p = 0.706). No significant changes were found in the control group. Furthermore, E/I MLA and RVC856-950 decreased significantly after BT by 12.65% and 1.77% (p < 0.001), respectively.
CONCLUSION: BT significantly reduced airway narrowing and air-trapping in patients with severe asthma. This can be interpreted as direct therapeutic effects caused by a reduction in airway-smooth muscle mass and changes in innervation. A reduction in air-trapping indicates an influence on more peripheral airways not directly treated by the BT procedure.
引用
- Konietzke P, Weinheimer O, Wielpütz MO, et al. Quantitative CT detects changes in airway dimensions and air-trapping after bronchial thermoplasty for severe asthma. Eur J Radiol. 2018. PMID: 30292270. doi:10.1016/j.ejrad.2018.08.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。