文献速递胸部介入CTDSA

金属支架置入与取出治疗气管切开后及插管后气管狭窄

Metallic stent insertion and removal for post-tracheotomy and post-intubation tracheal stenosis.
PubMed 文献 · Radiol Med · 2018-10-24

回顾性分析32例气管切开后或插管后气管狭窄患者,透视下置入38枚自膨式金属气道支架并尝试取出。35枚支架成功取出,技术成功率92.1%,取出相关并发症6例、无死亡;1年、3年、5年通畅率分别为87.1%、76.2%、70.8%,两种病因间无显著差异。作者认为透视下置入与取出安全有效,3个月留置时间合理。

要点

  • 透视下气道金属支架置入与取出技术成功率高,取出技术成功率为92.1%。
  • 支架置入后最常见并发症为膨胀不充分与组织增生。
  • 1年、3年、5年通畅率分别为87.1%、76.2%、70.8%,两种病因间无显著差异。

核心结论

  • 透视下置入与取出气道支架对插管后及气管切开后气管狭窄安全有效。
  • 作者认为气道支架留置3个月是合理的。

研究设计与样本

  • 回顾性分析2011年9月至2017年3月接受透视下支架置入的32例患者,年龄12至69岁。
  • 共置入38枚气道支架,其中覆膜支架35枚、裸支架3枚;19枚支架用于16例插管后或气管切开后气管狭窄患者。
  • 所有患者在支架取出前接受胸部CT检查,伴或不伴支气管镜检查。

关键影像表现/征象

  • 支架置入后最常见并发症为膨胀不充分与组织增生。
  • 取出后4枚支架出现支架丝断裂,其中3枚支架碎片残留。
  • 2例气管切开后气管狭窄患者取出后立即出现呼吸困难并需要机械通气。

诊断标准与关键数值

  • 38枚支架中35枚经透视成功取出,技术成功率为92.1%。
  • 常规取出在2.9±0.3个月后进行,支架再狭窄在平均2.7±0.3个月后发现。
  • 1年、3年、5年通畅率分别为87.1%、76.2%、70.8%,插管后与气管切开后气管狭窄之间无显著差异。

临床应用与阅片要点

  • 支架取出前应行胸部CT检查,伴或不伴支气管镜检查。
  • 取出相关并发症共6例、无死亡,包括支架丝断裂伴碎片残留及取出后立即呼吸困难需机械通气。
  • 1例气管切开后气管狭窄患者在平均33.7±3.9个月随访期间失访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study the safety and effectiveness of fluoroscopic insertion and removal of self-expandable metallic airway stent for post-tracheotomy tracheal stenosis (PTTS) and post-intubation tracheal stenosis (PITS).

METHODS: We conducted a retrospective analysis of 32 patients who underwent fluoroscopic stenting from September 2011 to March 2017. The patients ranged in age from 12 to 69 years. Thirty-eight airway stents were implanted, 35 covered stents and three bare stents. Nineteen airway stents were used for 16 cases of PITS or PTTS. All patients underwent chest CT scans with/without bronchoscopy prior to stent removal. The indication of stent removal and post-interventional complications were analyzed.

RESULTS: All 38 airway stents were successfully inserted. Insufficient expansion and tissue hyperplasia were most common complications after stenting. Thirty five of 38 airway stents were successfully removed fluoroscopically, with a technical success rate of 92.1%. Routine removal was performed after 2.9 ± 0.3 months, and stent restenosis was found after a mean duration of 2.7 ± 0.3 months. There were six complications of stent removal with no death. Four stents showed strut fracture after removal, of which three stent pieces retained. Two patients showed dyspnea immediately after removal and required mechanical ventilation in PTTS. One patient with PTTS lost of follow-up during a mean period of 33.7 ± 3.9 months. The one-, three- and five-year patency rates were 87.1%, 76.2% and 70.8%, respectively. There was no significant difference between PITS and PTTS.

CONCLUSIONS: Fluoroscopic insertion and removal of airway stent is safe and effective for PITS and PTTS. A three-month retention time is reasonable for airway stents.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Bi Y, Yu Z, Ren J, et al. Metallic stent insertion and removal for post-tracheotomy and post-intubation tracheal stenosis. Radiol Med. 2018. PMID: 30357596. doi:10.1007/s11547-018-0953-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。