文献速递头颈技术与安全PETCT

FDG PET/CT在鼻腔鼻窦肿瘤表征中的应用:标准化摄取值参数分析

Utility of FDG PET/CT in the Characterization of Sinonasal Neoplasms: Analysis of Standardized Uptake Value Parameters.
PubMed 文献 · AJR Am J Roentgenol · 2018-10-09

回顾性纳入97例病理证实的未经治疗鼻腔鼻窦肿瘤患者,分析治疗前FDG PET/CT的SUVmax、SUVmean及SUVratio(原发肿瘤SUVmax与纵隔血池SUVmean比值)在不同组织病理亚型间的差异。各参数在组织病理类型间有显著差异,SNUC、SCC等部分亚型间参数值更高,但部分罕见组织学亚型间FDG摄取存在重叠,仍需手术活检鉴别。

要点

  • 鼻腔鼻窦肿瘤的SUVmax、SUVmean、SUVratio在组织病理类型间有显著差异(p<0.05)。
  • SNUC的SUVmax、SUVmean、SUVratio高于嗅神经母细胞瘤、转移瘤和腺样囊性癌(p<0.05)。
  • 部分罕见组织学亚型间FDG摄取存在重叠,仍需手术活检鉴别组织学亚型。

核心结论

  • FDG PET/CT的不同SUV参数可作为所谓「代谢活检」将鼻腔鼻窦肿瘤归入不同组织病理亚群,有助于部分较常见亚型的表征;但部分罕见组织学亚群间FDG摄取存在重叠,侵袭性鼻腔鼻窦肿块的组织学亚型鉴别仍需手术活检。

研究设计与样本

  • 回顾性研究纳入97例连续患者(男58例、女39例;年龄20-93岁,平均62岁),均为病理证实的未经治疗鼻腔鼻窦肿瘤,于2010年2月至2017年8月行FDG PET/CT;对原发肿瘤行半定量分析,评估SUVmax、SUVmean及SUVratio(原发肿瘤SUVmax与纵隔血池SUVmean比值),分析14个鼻腔鼻窦肿瘤组织病理亚组,采用Kruskal-Wallis检验比较各参数与组织病理诊断。

诊断标准与关键数值

  • 鼻腔鼻窦肿瘤整体SUVmax均值16.6±9.7、SUVmean均值8.6±5.1、SUVratio均值5.9±3.7,各参数在组织病理类型间有显著差异(p<0.05)。SNUC的SUVmax、SUVmean、SUVratio均值高于嗅神经母细胞瘤、转移瘤和腺样囊性癌(p<0.05)。SCC的SUVmax和SUVmean均值高于嗅神经母细胞瘤和转移瘤(p<0.05)。SCC和SNUC的SUVmax均值高于低分化癌(p<0.05)。SCC的SUVratio均值高于小细胞癌、嗅神经母细胞瘤和腺样囊性癌(p<0.05)。

临床应用与阅片要点

  • 作者认为FDG PET/CT的不同SUV参数可作为所谓「代谢活检」帮助将鼻腔鼻窦肿瘤归入不同组织病理亚群,有助于部分较常见亚型的表征;但作者同时指出部分罕见组织学亚群间FDG摄取存在重叠,侵袭性鼻腔鼻窦肿块的组织学亚型鉴别仍需手术活检。

局限性

  • 原文指出部分罕见组织学亚群间FDG摄取存在重叠,故侵袭性鼻腔鼻窦肿块的组织学亚型鉴别仍需手术活检。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We aimed to evaluate the contribution of different standardized uptake value (SUV) parameters generated from pretreatment 18F-FDG PET/CT in the characterization of sinonasal neoplasms with histopathologic correlations.

MATERIALS AND METHODS: This retrospective study included 97 consecutive patients (58 men, 39 women; age range, 20-93 years; mean age, 62 years) with pathologically proven untreated sinonasal neoplasms who underwent FDG PET/CT from February 2010 to August 2017. Semiquantitative analysis of primary tumors were performed to evaluate the maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), and the ratio of the SUVmax of the primary tumor to the SUVmean of mediastinal blood pool, which we refer to here as " SUVratio." Various sinonasal tumor histopathologic subgroups (n = 14) were analyzed. The Kruskal-Wallis test was used to compare the SUVmax, SUVmean, and SUVratio with the histopathologic diagnosis.

RESULTS: Mean values of SUVmax, SUVmean, and SUVratio for the sinonasal neoplasms were 16.6 ± 9.7 (SD), 8.6 ± 5.1, and 5.9 ± 3.7, respectively, and each parameter was significantly different between histopathologic types (p < 0.05). Mean values of SUVmax, SUVmean, and SUVratio were higher in sinonasal undifferentiated carcinoma (SNUC) than in olfactory neuroblastoma, metastasis, and adenoid cystic carcinoma (p < 0.05). Mean values of SUVmax and SUVmean were higher in squamous cell carcinoma (SCC) than in olfactory neuroblastoma and metastasis (p < 0.05). Also, mean SUVmax was higher in SCC and SNUC than in poorly differentiated carcinoma (p < 0.05). Mean SUVratio was higher in SCC than in small cell carcinoma, olfactory neuroblastoma, and adenoid cystic carcinoma (p < 0.05).

CONCLUSION: We conclude that different SUV parameters from FDG PET/CT can be used as so-called "metabolic biopsy" to categorize sinonasal neoplasms into different histopathologic subgroups because it can help in the characterization of some of the more common subgroups of sinonasal neoplasms. However, we found that there is overlap in FDG uptake values among some of the rare histologic subgroups; hence, surgical biopsy is still needed for differentiation of histologic subtypes of aggressive sinonasal masses.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Ozturk K, Gencturk M, Caicedo-Granados E, et al. Utility of FDG PET/CT in the Characterization of Sinonasal Neoplasms: Analysis of Standardized Uptake Value Parameters. AJR Am J Roentgenol. 2018. PMID: 30300005. doi:10.2214/AJR.18.19501

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。