回顾性纳入29例临床T2N0口腔舌癌手术患者,两名医师独立选择MRI序列并勾画肿瘤,采用三种方法测量MRI浸润深度并共识选择最优方法(方法4)。方法2和方法4的观察者间信度优秀(ICC分别为0.829和0.807),方法4与病理测量相关性良好(ICC=0.611),但MRI测量值均比病理大2-3mm;MRI浸润深度小于5mm的患者无淋巴结复发。

要点

  • 方法2和方法4的观察者间信度优秀,ICC分别为0.829和0.807。
  • 方法4与病理测量相关性良好(ICC=0.611),但MRI测量值均比病理大2-3mm。
  • MRI浸润深度小于5mm的患者无淋巴结复发。

核心结论

  • MRI所测浸润深度对术前分期有价值,最佳测量方法应逐例选择。

研究设计与样本

  • 回顾性研究,29例临床T2N0口腔舌癌手术患者,术前3T超导MRI,两名分别有23年和18年头颈部MRI经验的医师独立选择序列、勾画肿瘤并测量。

关键影像表现/征象

  • MRI所测浸润深度均比病理测量值大2-3mm。
  • MRI浸润深度小于5mm的患者无淋巴结复发。

诊断标准与关键数值

  • 方法2(轴位浸润部分)观察者间ICC为0.829,信度优秀。
  • 方法4(逐例共识选择最优方法)观察者间ICC为0.807,信度优秀。
  • 方法4与病理测量ICC为0.611,相关性良好。

临床应用与阅片要点

  • MRI所测浸润深度可用于术前分期。
  • 最佳测量方法应逐例选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: To evaluate the inter-rater reliability of the magnetic resonance imaging (MRI)-derived depth of invasion (DOI) and the agreement between MRI and pathological measurements of oral tongue cancer.

MATERIALS AND METHODS: The institutional review board approved this retrospective study. The study population consisted of 29 patients with clinical T2N0 oral tongue cancer treated by surgery. Routine pretreatment MRI was performed on a 3T superconducting imager. Two raters with 23 and 18 years of head-and-neck MRI experience, respectively, independently chosen MRI sequences for each patient, then delineate the tumor, and then used three protocols to measure the MRI-derived DOI: the axial reconstructed thickness (method 1), the axial invasive portion (method 2), and the coronal invasive portion (method 3). Then they consensually selected the optimal among the three methods for each patient; it was designated method 4. The Bland-Altman plots, intraclass correlation coefficients (ICCs), and the paired samples test were used. According to the median follow-up of 41 months, the relationship between the MRI-derived DOI and nodal recurrence was also investigated.

RESULTS: The inter-rater reliability of methods 2 and 4 was excellent (ICC of 0.829 and 0.807, respectively). The correlation between MRI and pathological measurements was good for method 4 (ICC of 0.611), however, all measurements recorded on MRI were 2-3 mm larger than on pathology. No patients whose MRI-derived DOI was less than 5 mm suffered nodal recurrence.

CONCLUSION: The MRI-derived DOI was valuable for the preoperative staging. The optimal measurement method should be selected on a case-by-case basis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Murakami R, Shiraishi S, Yoshida R, et al. Reliability of MRI-Derived Depth of Invasion of Oral Tongue Cancer. Acad Radiol. 2018. PMID: 30268718. doi:10.1016/j.acra.2018.08.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。