应用定量磁化率成像测量人胎儿上矢状窦血氧饱和度

Quantitative susceptibility mapping in the human fetus to measure blood oxygenation in the superior sagittal sinus.
PubMed 文献 · Eur Radiol · 2018-10-01

本研究纳入21例健康孕妇(中位孕周31.3周,四分位距8.8周),采用改良QSM处理流程从SWI相位图像生成磁化率图,量化上矢状窦磁化率差Δχv并推算血氧饱和度SvO2。结果显示SSS平均Δχv为0.42±0.03 ppm,推算平均SvO2为67%±7%,与已发表研究一致;模拟显示在包含SSS周围至少5个体素和5层图像的掩模下,不同血管方向相对主磁场的SvO2系统误差<3%。结论认为QSM用于人胎儿脑静脉血磁化率和氧合测量是可行的。

要点

  • 改良QSM流程可在人胎儿上矢状窦测量磁化率差Δχv并推算静脉血氧饱和度SvO2。
  • SSS平均Δχv为0.42±0.03 ppm,推算平均SvO2为67%±7%。
  • 包含SSS周围至少5个体素和5层图像的掩模下,SvO2系统误差<3%。

核心结论

  • 这项在体研究证明,使用QSM可在人胎儿脑内估算Δχv和SvO2,胎儿上矢状窦推算平均SvO2为67%±7%,与已发表研究一致。

研究设计与样本

  • 可行性在体研究,纳入健康孕妇21例(中位孕周31.3周,四分位距8.8周),采集SWI数据,采用针对胎儿应用优化的改良QSM处理流程生成磁化率图,并通过模拟研究改良流程所致SvO2系统误差。

关键影像表现/征象

  • 从SWI相位图像经改良QSM流程生成胎儿脑磁化率图,处理流程包括轻度高通滤波后对相位图二次拟合消除背景相位、手动创建包含上矢状窦的胎儿脑掩模、对掩模相位图采用几何约束的截断k空间方法逆滤波。
  • 所有孕周SSS平均Δχv为0.42±0.03 ppm。
  • 基于Δχv推算所有胎儿SSS平均SvO2为67%±7%。

诊断标准与关键数值

  • 模拟显示,当掩模包含SSS周围至少5个体素和5层图像时,不同血管方向相对主磁场的SvO2系统误差<3%。
  • SSS平均Δχv为0.42±0.03 ppm,对应推算平均SvO2为67%±7%。

临床应用与阅片要点

  • 在胎儿QSM中,掩模需包含SSS周围至少5个体素和5层图像,以将SvO2系统误差控制在<3%。
  • 处理流程包括轻度高通滤波后二次拟合消除背景相位、手动创建含SSS的胎儿脑掩模、几何约束截断k空间逆滤波。
  • 原文报告SSS推算平均SvO2为67%±7%,与已发表研究一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To present the feasibility of performing quantitative susceptibility mapping (QSM) in the human fetus to evaluate the oxygenation (SvO2) of cerebral venous blood in vivo.

METHODS: Susceptibility weighted imaging (SWI) data were acquired from healthy pregnant subjects (n = 21, median = 31.3 weeks, interquartile range = 8.8 weeks). The susceptibility maps were generated from the SWI-phase images using a modified QSM processing pipeline, optimised for fetal applications. The processing pipeline is as follows: (1) mild high-pass filtering followed by quadratic fitting of the phase images to eliminate background phase variations; (2) manual creation of a fetal brain mask that includes the superior sagittal sinus (SSS); (3) inverse filtering of the resultant masked phase images using a truncated k-space approach with geometric constraint. Further, the magnetic susceptibility, ∆χv and corresponding putative SvO2 of the SSS were quantified from the generated susceptibility maps. Systematic error in the measured SvO2 due to the modified pipeline was also studied through simulations.

RESULTS: Simulations showed that the systematic error in SvO2 when using a mask that includes a minimum of 5 voxels around the SSS and five slices remains < 3% for different orientations of the vessel relative to the main magnetic field. The average ∆χv in the SSS quantified across all gestations was 0.42 ± 0.03 ppm. Based on ∆χv, the average putative SvO2 in the SSS across all fetuses was 67% ± 7%, which is in good agreement with published studies.

CONCLUSIONS: This in vivo study demonstrates the feasibility of using QSM in the human fetal brain to estimate ∆χv and SvO2.

KEY POINTS: • A modified quantitative susceptibility mapping (QSM) processing pipeline is tested and presented for the human fetus. • QSM is feasible in the human fetus for measuring magnetic susceptibility and oxygenation of venous blood in vivo. • Blood magnetic susceptibility values from MR susceptometry and QSM agree with each other in the human fetus.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yadav BK, Buch S, Krishnamurthy U, et al. Quantitative susceptibility mapping in the human fetus to measure blood oxygenation in the superior sagittal sinus. Eur Radiol. 2018. PMID: 30276673. doi:10.1007/s00330-018-5735-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。