经食管超声测量上腔静脉预测有创正压通气患者容量反应性
纳入36例择期全麻有创正压通气下胃肠手术患者,麻醉诱导后记录每搏量变异度、上腔静脉直径、平均动脉压、中心静脉压和脉搏,并在液体负荷后复测。液体负荷后上腔静脉直径明显增大,上腔静脉变异度和每搏量变异度显著降低(P < .05)。上腔静脉最小直径预测容量反应性的AUC为0.929,可能是有创正压通气患者预测容量反应性的有效指标。
要点
- 上腔静脉最小直径预测容量反应性的AUC为0.929,优于上腔静脉变异度(AUC 0.849)。
- 液体负荷后上腔静脉直径明显增大,上腔静脉变异度和每搏量变异度显著降低(P < .05)。
- 上腔静脉最小直径最佳截断值为1.135 cm,上腔静脉变异度最佳截断值为21.1%。
核心结论
- 上腔静脉最小直径可能是有创正压通气患者预测容量反应性的有效指标。
研究设计与样本
- 研究纳入36例择期全麻有创正压通气下胃肠手术患者,麻醉诱导后记录每搏量变异度、上腔静脉直径、平均动脉压、中心静脉压和脉搏,液体负荷后复测并计算上腔静脉变异度。
诊断标准与关键数值
- 上腔静脉变异度预测容量反应性的最佳截断值为21.1%,AUC为0.849。
- 上腔静脉最小直径预测容量反应性的最佳截断值为1.135 cm,AUC为0.929。
- 上腔静脉最大直径预测容量反应性的最佳截断值为1.480 cm,AUC为0.862。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Preoperative fasting, water deprivation, and intraoperative fluid loss and redistribution result in hypovolemia in patients undergoing surgery. Some findings have indicated that the superior vena cava (SVC) diameter and variation, as determined by transesophageal echocardiography during surgery, do not reflect central venous pressure effectively. This study aimed to compare and correlate the SVC diameter and variation with the stroke volume variation for predicting fluid responsiveness in patients undergoing invasive positive pressure ventilation.
METHODS: Thirty-six patients scheduled for elective gastrointestinal surgery under general anesthesia with invasive positive pressure ventilation were included in this study. After anesthesia induction, the stroke volume variation, SVC diameter, mean arterial pressure, central venous pressure, and pulse were recorded, and measurements after fluid challenge were recorded as well. The SVC variation was calculated before and after the fluid challenge.
RESULTS: After the fluid challenge, the SVC diameter markedly increased, whereas the SVC variation and stroke volume variation significantly decreased (P < .05). The optimal cutoff value for the SVC variation was 21.1%, and the area under the curve (AUC) from a receiver operating characteristic curve analysis was 0.849. The optimal cutoff value for the minimal SVC diameter was 1.135 cm, and that AUC was 0.929. In addition, the optimal cutoff value for the maximal SVC diameter was 1.480 cm, and the AUC was 0.862.
CONCLUSIONS: The minimal SVC diameter may be an effective indicator for predicting fluid responsiveness in patients undergoing invasive positive pressure ventilation.
引用
- Cheng Z, Yang QQ, Zhu P, et al. Transesophageal Echocardiographic Measurements of the Superior Vena Cava for Predicting Fluid Responsiveness in Patients Undergoing Invasive Positive Pressure Ventilation. J Ultrasound Med. 2018. PMID: 30298577. doi:10.1002/jum.14839
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。