文献速递神经头颈MRPETCT

治疗后胶质瘤患者的交叉性小脑失联络:动脉自旋标记与动态磁敏感对比的对比研究

Crossed cerebellar diaschisis in post-treatment glioma patients: A comparative study of arterial spin labelling and dynamic susceptibility contrast.
PubMed 文献 · Eur J Radiol · 2018-08-03

回顾性纳入130例同时行DSC与ASL的胶质瘤治疗后患者,其中16例有18F-FDG PET/CT;累及放射冠、基底节和岛叶的幕上病灶与CCD发生显著相关,CCD阳性组病灶更大;以PET为参考,ASL-CBF与DSC-rCBF诊断效能最佳,两法一致性好。

要点

  • 幕上病灶累及放射冠、基底节和岛叶时CCD发生风险显著增加。
  • CCD阳性组幕上病灶显著大于CCD阴性组。
  • ASL-CBF与DSC-rCBF诊断CCD的准确率均为83.3%,AUC分别为0.967和0.983。

核心结论

  • CCD可出现在治疗后胶质瘤患者中,并可在ASL-CBF、DSC-rCBF和DSC-rCBV图等MR灌注图像上检出。

研究设计与样本

  • 回顾性研究纳入130例同时行DSC和ASL的胶质瘤治疗后患者,其中16例行18F-FDG PET/CT。
  • 以PET为参考标准,比较ASL与DSC各灌注图对CCD的诊断效能。
  • 计算双侧小脑不对称指数(AI),分析ASL-CBF、DSC-rCBF与DSC-rCBV图AI值的相关性。

关键影像表现/征象

  • 幕上病灶累及放射冠(P < 0.001)、基底节(P < 0.001)和岛叶(P = 0.046)与CCD发生显著相关。
  • CCD阳性组病灶尺寸显著大于CCD阴性组(P = 0.005)。
  • ASL图所示灌注不对称程度较DSC图更显著。

诊断标准与关键数值

  • 以PET为参考,ASL-CBF与DSC-rCBF诊断准确率均为83.3%,AUC分别为0.967和0.983,两者差异无统计学意义。
  • ASL与DSC检测CCD的组间一致性的κ值为0.893。

临床应用与阅片要点

  • 阅片时对累及放射冠、基底节或岛叶的较大幕上病灶,应留意对侧小脑灌注是否减低以提示CCD。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess crossed cerebellar diaschisis (CCD) in post-treatment glioma patients, and to compare the performance of arterial spin labelling (ASL) and dynamic susceptibility contrast (DSC) in detecting CCD.

METHODS AND MATERIALS: This retrospective study included 130 patients who had both DSC and ASL. Among them, 16 had underwent fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). We investigated the relationship between CCD and the location and size of supratentorial lesions, and compared PET diagnostic performance with that of ASL and DSC. We assessed the inter-methods agreement for ASL and DSC, and performed quantitative analysis by calculating the asymmetry index (AI) between bilateral cerebellum and exploring how the AI values for ASL-CBF, DSC-rCBF, and DSC-rCBV maps correlated with each other.

RESULT: Supratentorial lesions affecting the corona radiata (P < 0.001), basal ganglia (P < 0.001), and insula (P = 0.046) were significantly associated with the occurrence of CCD. Lesion size was significantly larger (P = 0.005) in the CCD positive group. With PET as a reference, ASL-CBF and DSC-rCBF maps exhibited the best diagnostic performance compared with the other DSC-generated maps (diagnostic accuracy = 83.3% for both, area under curve (AUC) of ASL = 0.967, AUC of rCBF = 0.983), although differences were not statistically significant. The κ value for the inter-methods (ASL and DSC) agreement in detecting CCD was 0.893, while the degree of perfusion asymmetry was more significant in ASL- than DSC-generated maps. Bland-Altman plots showed that the AI for ASL-CBF was moderately correlated with those for DSC-rCBF and DSC-rCBV.

CONCLUSIONS: CCD can present in post-treatment glioma patients and is detectable on MR-perfusion images including ASL-CBF, DSC-rCBF, and DSC-rCBV maps.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Lin T, Lyu Y, Qu J, et al. Crossed cerebellar diaschisis in post-treatment glioma patients: A comparative study of arterial spin labelling and dynamic susceptibility contrast. Eur J Radiol. 2018. PMID: 30292276. doi:10.1016/j.ejrad.2018.08.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。