儿童脑肿瘤中伪连续动脉自旋标记与动态磁敏感对比MRI在有无对比剂渗漏校正时的比较
前瞻性扫描15例儿童脑肿瘤患者,比较伪连续动脉自旋标记(ASL)脑血流量(CBF)与动态磁敏感对比(DSC)MRI脑血容量(CBV)在有无渗漏校正时的相关性。DSC有无渗漏校正的CBV值显著不同(p<0.01),ASL CBF与DSC CBV显著正相关(r=0.516,p=0.049),渗漏校正后相关性更强(r=0.728,p=0.002)。作者认为分析强化性儿童脑肿瘤DSC数据时应进行渗漏校正。
要点
- DSC有无渗漏校正的CBV值显著不同(p<0.01),T1强化肿瘤不校正时CBV图难以判读。
- ASL CBF与DSC CBV显著正相关(r=0.516,p=0.049),渗漏校正后更强(r=0.728,p=0.002)。
- 作者认为分析强化性儿童脑肿瘤DSC数据时应进行渗漏校正。
核心结论
- DSC有无渗漏校正的CBV值显著不同,高度T1强化肿瘤渗漏校正后CBV大幅增加。
- DSC与ASL灌注指标在多种儿童脑肿瘤中显著相关,DSC数据渗漏校正后相关性更强。
- 作者认为分析强化性儿童脑肿瘤DSC数据时应进行渗漏校正。
研究设计与样本
- 前瞻性研究,15例儿童脑肿瘤患者,使用伪连续ASL和DSC-MRI(预注射以减少对比剂渗漏)扫描。
- ASL生成CBF图,DSC数据用Boxerman技术及渗漏参数K2生成有/无渗漏校正的CBV图。
- 组织学诊断包括毛细胞型星形细胞瘤7例、胶质母细胞瘤1例、髓母细胞瘤1例、第四脑室菊形团胶质神经元肿瘤1例、非典型脉络丛乳头状瘤1例、毛黏液样星形细胞瘤1例;3例为非侵袭性诊断的低级别胶质瘤。
关键影像表现/征象
- T1强化肿瘤的DSC CBV图不做渗漏校正时难以判读。
- 高度T1强化肿瘤渗漏校正后CBV大幅增加。
- K2值组间变异大(均值0.35,范围-0.49至0.64)。
诊断标准与关键数值
- 有/无渗漏校正的CBV值显著不同(p<0.01)。
- ASL CBF与DSC CBV显著正相关(r=0.516,p=0.049),渗漏校正后相关更强(r=0.728,p=0.002)。
临床应用与阅片要点
- 作者认为分析强化性儿童脑肿瘤DSC数据时应进行渗漏校正。
- ASL与DSC灌注指标在儿童脑肿瘤中显著相关,渗漏校正后相关性增强。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: To investigate correlations between MRI perfusion metrics measured by dynamic susceptibility contrast and arterial spin labelling in paediatric brain tumours.
METHODS:: 15 paediatric patients with brain tumours were scanned prospectively using pseudo-continuous arterial spin labelling (ASL) and dynamic susceptibility contrast (DSC-) MRI with a pre-bolus to minimise contrast agent leakage. Cerebral blood flow (CBF) maps were produced using ASL. Cerebral blood volume (CBV) maps with and without contrast agent leakage correction using the Boxerman technique and the leakage parameter, K2, were produced from the DSC data. Correlations between the metrics produced were investigated.
RESULTS:: Histology resulted in the following diagnoses: pilocytic astrocytoma (n = 7), glioblastoma (n = 1), medulloblastoma (n = 1), rosette-forming glioneuronal tumour of fourth ventricle (n = 1), atypical choroid plexus papilloma (n = 1) and pilomyxoid astrocytoma (n = 1). Three patients had a non-invasive diagnosis of low-grade glioma. DSC CBV maps of T1-enhancing tumours were difficult to interpret without the leakage correction. CBV values obtained with and without leakage correction were significantly different (p < 0.01). A significant positive correlation was observed between ASL CBF and DSC CBV (r = 0.516, p = 0.049) which became stronger when leakage correction was applied (r = 0.728, p = 0.002). K2 values were variable across the group (mean = 0.35, range = -0.49 to 0.64).
CONCLUSION:: CBV values from DSC obtained with and without leakage correction were significantly different. Large increases in CBV were observed following leakage correction in highly T1-enhancing tumours. DSC and ASL perfusion metrics were found to correlate significantly in a range of paediatric brain tumours. A stronger relationship between DSC and ASL was seen when leakage correction was applied to the DSC data. Leakage correction should be applied when analysing DSC data in enhancing paediatric brain tumours.
ADVANCES IN KNOWLEDGE:: We have shown that leakage correction should be applied when investigating enhancing paediatric brain tumours using DSC-MRI. A stronger correlation was found between CBF derived from ASL and CBV derived from DSC when a leakage correction was employed.