低剂量CT与X线摄影对骶髂关节辐射暴露的比较
研究分析36例因疑似肾绞痛行低剂量CT的患者,比较低剂量CT与骨盆及骶髂关节X线摄影对骶髂关节的有效剂量。低剂量CT对骶髂关节的最大有效剂量均低于1 mSv,平均0.42±0.18 mSv,所有CT图像均满足骶髂关节诊断质量;作者建议以低剂量CT替代X线摄影用于骶髂关节专门评估。
要点
- 低剂量CT评估骶髂关节的最大有效剂量均低于1 mSv,平均0.42±0.18 mSv。
- 骶髂关节X线摄影平均剂量0.15±0.10 mSv,单次骨盆X线摄影平均0.09±0.06 mSv。
- 所有低剂量CT图像对骶髂关节评估均达到诊断质量。
核心结论
- 低剂量骶髂关节CT可稳定实现有效辐射剂量低于1 mSv;鉴于X线摄影诊断骶髂关节炎的可靠性和敏感度较差,作者建议以低剂量CT替代X线摄影用于骶髂关节专门评估。
研究设计与样本
- 研究类型为影像剂量比较研究,纳入36例(女19例、男17例)因疑似肾绞痛行低剂量CT的患者,计算骶髂关节及髂嵴至骶髂关节下方1 cm扩展区域两个有效剂量估计值;36张骨盆前后位X线片和36张骶髂关节位X线片按年龄、性别和体宽与CT扫描匹配,X线有效剂量采用国际放射防护委员会第60号出版物所述方法估算。
诊断标准与关键数值
- 低剂量CT对骶髂关节的最大有效剂量在所有病例中均低于1 mSv,平均0.42±0.18 mSv(范围0.14–0.83 mSv)。
- 低剂量CT对扩展区域(髂嵴至骶髂关节下方1 cm)平均有效剂量0.57±0.24 mSv(范围0.19–1.11 mSv)。
- 骶髂关节X线摄影平均有效剂量0.15±0.10 mSv(范围0.07–1.38 mSv)。
- 单次骨盆X线摄影平均有效剂量0.09±0.06 mSv(范围0.04–0.37 mSv)。
- 所有低剂量CT研究对骶髂关节评估均达到诊断质量。
临床应用与阅片要点
- 作者建议以低剂量CT替代X线摄影用于骶髂关节专门评估,理由是X线摄影诊断骶髂关节炎的可靠性和敏感度较差。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The primary objective of this study was to estimate the effective dose delivered to the sacroiliac joint (SIJ) from low-dose (LD) CT compared with that from radiography. Secondary objectives included evaluation of diagnostic quality of LD CT of the SIJ and development of a clinical protocol for LD CT of the SIJ.
MATERIALS AND METHODS: Data from 36 patients (19 women, 17 men) undergoing LD CT for suspected renal colic were analyzed. Two effective dose estimates were calculated: one for the SIJ and another for an extended region from the iliac crest to 1 cm below the SIJ. Thirty-six anteroposterior pelvic and 36 SIJ view radiographs were age-, sex-, and body width-matched to CT scans. Effective dose from radiography was estimated using the method described in International Commission on Radiologic Protection Publication 60.
RESULTS: Maximum effective dose to the SIJ from LD CT was less than 1 mSv in all cases, with a mean ± SD of 0.42 ± 0.18 mSv (range, 0.14-0.83 mSv), whereas mean dose to the extended region was 0.57 ± 0.24 mSv (range, 0.19-1.11 mSv). Mean dose from SIJ radiographs was 0.15 ± 0.10 mSv (range, 0.07-1.38 mSv), and mean dose from a single pelvic radiograph was 0.09 ± 0.06 mSv (range, 0.04-0.37 mSv). All CT studies were of diagnostic quality for assessment of the SIJ.
CONCLUSION: LD CT of the SIJ can be consistently performed with an effective radiation dose of less than 1 mSv. Because reliability and sensitivity of radiography for sacroiliitis is poor, we recommend that LD CT replace radiography for dedicated evaluation of the SIJ.
引用
- Chahal BS, Kwan ALC, Dhillon SS, et al. Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography. AJR Am J Roentgenol. 2018. PMID: 30207791. doi:10.2214/AJR.18.19678
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。