眼内髓上皮瘤的常规、扩散及渗透性MR表现
回顾性分析5例儿童眼内髓上皮瘤的临床、病理及MRI资料,其中4例加做DWI并计算平均ADC,全部行DCE。肿瘤T1WI高信号、T2WI低信号,5例中2例见钙化、3例见囊腔,均不同程度强化;平均ADC为1.156 ± 242.75 × 10-3 mm2/s;时间-强度曲线以缓慢上升、>50%持续及一定程度廓清为主;畸胎样变异型的K-trans、AUC、VE、TME及持续型TIC比例高于非畸胎样变异型,平台型比例较低。
要点
- 眼内髓上皮瘤常规MRI表现为T1WI高信号、T2WI低信号,可伴钙化与囊腔,均有强化。
- DWI平均ADC为1.156 ± 242.75 × 10-3 mm2/s,程度中等偏高。
- 畸胎样变异型K-trans、AUC、VE、TME及持续型TIC比例高于非畸胎样变异型。
核心结论
- 常规MR表现与既往报道相似;平均ADC中等偏高;TIC呈缓慢上升并可见廓清;畸胎样变异型的K-trans、AUC、VE、TME更高;渗透性参数用于与类似病变鉴别尚需进一步研究。
研究设计与样本
- 回顾性分析5例儿童眼内髓上皮瘤的临床、组织病理及MRI资料,其中4例行DWI并计算平均ADC,全部行DCE;本文首次报道髓上皮瘤的扩散与灌注特征。
关键影像表现/征象
- 肿瘤在T1加权像上呈高信号,在T2加权像上呈低信号。
- 5例肿瘤中2例可检出钙化,3例可检出囊腔。
- 所有肿瘤均显示一定程度强化。
诊断标准与关键数值
- 4例平均ADC为1.156 ± 242.75 × 10-3 mm2/s。
- 平均ktrans、Ve、Kep、TME、AUC、SER及峰值强化分别为0.082 ± 0.054、0.19 ± 0.076、0.31 ± 0.084、0.97 ± 0.0784、1.22 ± 0.81、67.34 ± 31.7及14.84 ± 7.34。
- TIC显示缓慢上升比例很高、>50%持续及一定程度廓清。
临床应用与阅片要点
- 畸胎样变异型较非畸胎样变异型显示更高的K-trans、AUC、VE、TME及持续型TIC比例,平台型比例较低。
- 渗透性参数用于与模仿髓上皮瘤的病变鉴别尚需进一步研究。
局限性
- 本组为回顾性分析,样本量为5例儿童。
- DWI仅在4例患者中完成,平均ADC计算受本组患者技术条件限制。
- 渗透性参数用于鉴别诊断尚需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To describe the neuroradiological features of intraocular medulloepithelioma.
METHODS: We retrospectively analyzed the clinical, histopathological, and MRI data of five children with medulloepithelioma. In addition to conventional images, DWI was performed in four patients and mean ADC was calculated; this was limited to the technique of this cohort of patients. DCE was performed in all patients. This is the first paper that presents diffusion and perfusion characteristics of medulloepithelioma.
RESULTS: Four tumors were malignant teratoid variants, two non-teratoid variants. Tumors were hyperintense on T1-weighted images and hypointense on T2-weighted images. Calcifications were detectable in two out of five tumors. Cavities were detectable in three out of five tumors. All tumors showed some degree of enhancement. The mean ADC of all four patients was 1.156 ± 242.75 × 10-3 mm2/s. Mean ktrans, Ve, Kep, TME, AUC, SER, and peak enhancement were 0.082 ± 0.054, 0.19 ± 0.076, 0.31 ± 0.084, 0.97 ± 0.0784, 1.22 ± 0.81, 67.34 ± 31.7, and 14.84 ± 7.34 respectively. TICs showed a very high ratio of slow increase, > 50% persistence and some degree of wash out. Teratoid variants showed higher K-trans, AUC, VE, TME, and persistent TIC pattern than non-teratoid ones, while plateau pattern ratio was lower.
CONCLUSION: Conventional MR findings were similar to previously reported cases. Mean ADCs were moderately high. TICs showed slow increase and presence of wash out. K-trans, AUC, VE, and TME were higher in teratoid variants. Permeability parameters in differential diagnosis with lesions mimicking medulloepithelioma need further investigations.
引用
- Galluzzi P, Casseri T, Cerase A, et al. Conventional, diffusion, and permeability MR findings in ocular medulloepithelioma. Neuroradiology. 2018. PMID: 30232518. doi:10.1007/s00234-018-2094-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。