文献速递外周血管骨肌US

超声射频数据技术评估强直性脊柱炎患者的亚临床动脉粥样硬化

Evaluation of subclinical atherosclerosis using ultrasound radiofrequency data technology in patients diagnosed with ankylosing spondylitis.
PubMed 文献 · J Ultrasound Med · 2018-09-04

研究纳入38例强直性脊柱炎患者和49例健康对照,采用多普勒超声射频法测量双侧颈总动脉内膜中层厚度和动脉僵硬度。患者与对照之间各项颈动脉指标均无统计学显著差异;病程及诊断治疗时长与α僵硬度指数和脉搏波速度呈中度正相关;Bath强直性脊柱炎疾病活动指数评分≥4分者的平均内膜中层厚度和弹性系数值高于评分<4分者。

要点

  • 强直性脊柱炎患者与健康对照的颈总动脉内膜中层厚度及僵硬度指标均无统计学显著差异。
  • 病程及诊断治疗时长与α僵硬度指数和脉搏波速度呈中度正相关。
  • 疾病活动指数评分≥4分者平均内膜中层厚度和弹性系数值高于评分<4分者。

核心结论

  • 低疾病活动度的强直性脊柱炎患者亚临床动脉粥样硬化未见加速,但疾病活动控制不充分可能导致颈动脉内膜中层厚度增加和动脉粥样硬化形成;射频数据技术可无创、定量显示颈总动脉内膜中层厚度升高和血管弹性下降。

研究设计与样本

  • 研究共纳入87名参与者,其中38例强直性脊柱炎患者和49例健康对照,采用多普勒超声射频法测量双侧颈总动脉内膜中层厚度和动脉僵硬度。

诊断标准与关键数值

  • 右侧颈总动脉、左侧颈总动脉、内膜中层厚度、扩张系数、弹性系数、α和β僵硬度指数及脉搏波速度在强直性脊柱炎患者与健康对照间均无统计学显著差异(P > .05)。
  • 强直性脊柱炎患者病程与α僵硬度指数和脉搏波速度呈中度正相关(P < .05)。
  • 强直性脊柱炎患者诊断和治疗时长与α僵硬度指数、β僵硬度指数及脉搏波速度呈中度正相关(P < .05)。
  • Bath强直性脊柱炎疾病活动指数评分≥4分的强直性脊柱炎患者平均内膜中层厚度和弹性系数值高于评分<4分者(分别为P = .038和P = .33)。

临床应用与阅片要点

  • 作者认为射频数据技术可无创、定量显示强直性脊柱炎患者颈总动脉内膜中层厚度升高和血管弹性下降。
  • 作者认为疾病活动控制不充分可能导致颈动脉内膜中层厚度增加和动脉粥样硬化形成。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The present study aims to identify the cardiovascular risk associated with chronic inflammation and disease activity in patients with ankylosing spondylitis (AS) using noninvasive ultrasonographic radiofrequency data technology.

METHODS: In this study, a total of 87 participants, 38 patients with AS and 49 healthy controls, were evaluated by Doppler ultrasonography. Intima-media thickness (IMT) and arterial stiffness were measured from the bilateral common carotid artery using the radiofrequency method.

RESULTS: No statistically significant difference was found between the AS patients and healthy controls concerning the right common carotid artery, left common carotid artery, IMT, distensibility coefficient, elasticity coefficient, α and β stiffness indexes, and pulse wave velocities (P > .05). The symptom duration of the AS patients had a positive correlation that was moderate and was detected with the α stiffness index and pulse wave velocity (P < .05). The duration of diagnosis and treatment of the AS patients had a positive correlation that was moderate, was detected with the α stiffness index, the β stiffness index, and pulse wave velocity (P < .05). The mean IMT and elasticity coefficient values of the AS patients whose Bath Ankylosing Spondylitis Disease Activity Index score was 4 and above, were substantially higher than the values in the patients with scores lower than 4 (P = .038 and P = .33, respectively).

CONCLUSIONS: Subclinical atherosclerosis is not accelerated in AS patients with low disease activity, although insufficiently controlled disease activity may result in increased carotid IMT and atheromatosis. Radiofrequency data technology provides a noninvasive method for accurately and quantitatively demonstrating CCA-IMT elevation and the decrease in vascular elasticity in patients with AS.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kaplanoglu H, Özişler C. Evaluation of subclinical atherosclerosis using ultrasound radiofrequency data technology in patients diagnosed with ankylosing spondylitis. J Ultrasound Med. 2018. PMID: 30182506. doi:10.1002/jum.14754

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。