颈动脉超声造影对血管外膜滋养血管定量的自动分析方法
研究开发了颈动脉超声造影图像中血管外膜滋养血管新生自动分析与定量方法,并在186人(63名健康志愿者)队列中测试。自动单参数策略的AUROC低于手动Arcidiacono法,但自动多参数策略的AUROC显著优于手动法。
要点
- 自动多参数策略AUROC为78–90,优于手动Arcidiacono法的68–82。
- 自动单参数策略AUROC为60–63,低于手动Arcidiacono法。
- 超声造影可直接、定量、无创显示颈动脉血管外膜滋养血管。
核心结论
- 自动多参数策略是手动Arcidiacono法的有价值替代方案,同时提高诊断速度和诊断准确性。
研究设计与样本
- 研究为方法开发与验证,纳入186人,其中63名为健康志愿者。
关键影像表现/征象
- 心血管危险因素存在时,血管外膜滋养血管异常增殖,研究报道其为动脉粥样硬化病变的第一阶段。
诊断标准与关键数值
- 手动Arcidiacono法的AUROC大于68且小于82。
- 自动单参数策略的AUROC大于60且小于63。
- 自动多参数策略的AUROC大于78且小于90,显著优于手动Arcidiacono法。
临床应用与阅片要点
- 计算机辅助方法可加速超声造影图像分析并消除用户主观性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Adventitial vasa vasorum are physiologic microvessels that nourish artery walls. In the presence of cardiovascular risk factors, these microvessels proliferate abnormally. Studies have reported that they are the first stage of atheromatous disease. Contrast-enhanced ultrasound (CEUS) of the carotid allows direct, quantitative and non-invasive visualization of the adventitial vasa vasorum. Hence, the development of computer-assisted methods that speed image analysis and eliminate user subjectivity is important. We developed methods for automatic analyses and quantification of vasa vasorum neovascularization in CEUS and tested these methods in a cohort of 186 individuals, 63 of whom were healthy volunteers. We implemented alternative automatic strategies for using the images to stratify patients according to their risk group and compare the strategies with respect to diagnostic performance. An automatic single-parameter strategy performs less effectively than the corresponding Arcidiacono method based on manual interpretation of the images (68 < area under the receiver operating characteristic curve [AUROC] for the manual Arcidiacono method < 82; 60 < AUROC for the automatic single-parameter strategy < 63). However, by use of additional image parameters, an automatic multiparameter strategy has significantly improved performance with respect to the manual Arcidiacono method (78 < AUROC < 90). The automatic multiparameter strategy is a valuable alternative to the manual Arcidiacono method, improving both diagnostic speed and diagnostic accuracy.
引用
- Pereira T, Muguruza J, Mária V, et al. Automatic Methods for Carotid Contrast-Enhanced Ultrasound Imaging Quantification of Adventitial Vasa Vasorum. Ultrasound Med Biol. 2018. PMID: 30205994. doi:10.1016/j.ultrasmedbio.2018.07.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。