头颈部CT血管成像中联合自适应统计迭代重建-V与低管电压可在降低辐射剂量的同时获得更优图像质量

Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose.
PubMed 文献 · Acad Radiol · 2018-09-05

研究将121例患者随机分为三组:A组采用120 kVp联合滤波反投影,B组采用120 kVp联合50% ASIR-V,C组采用100 kVp联合50% ASIR-V,均行头颈部CT血管成像。结果显示C组辐射剂量最低,较A组降低40%,且动脉强化程度、信噪比和对比噪声比均更高、噪声更低,主观图像质量优于A组和B组。

要点

  • 100 kVp联合50% ASIR-V方案较常规120 kVp联合滤波反投影方案辐射剂量降低40%。
  • 100 kVp联合50% ASIR-V方案的动脉强化程度高于120 kVp联合50% ASIR-V方案和常规方案。
  • 两名放射科医师主观图像质量评价的一致性高(k=0.783)。

核心结论

  • 与常规方案相比,头颈部CT血管成像采用100 kVp联合50% ASIR-V方案可在更低辐射剂量下获得更优的客观和主观图像质量。

研究设计与样本

  • 随机对照研究,共纳入121例患者,随机分为三组,均使用256层CT扫描仪行头颈部CT血管成像。

诊断标准与关键数值

  • A组(常规方案):120 kVp联合滤波反投影;B组:120 kVp联合50% ASIR-V;C组:100 kVp联合50% ASIR-V。
  • C组容积CT剂量指数、剂量长度乘积和有效剂量较A组均降低40%(p<0.01)。
  • C组动脉强化程度高于A组和B组(p<0.01)。
  • B组和C组的信噪比和对比噪声比高于A组,噪声低于A组。
  • C组主观图像质量优于A组和B组(p<0.05),两名医师间一致性k=0.783。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate image quality and radiation exposure when using the adaptive statistical iterative reconstruction-V (ASIR-V) algorithm for reconstructing craniocervical computed tomographic angiography images acquired at 100 kVp.

MATERIALS AND METHODS: We randomly divided 121 patients into three groups: group A (conventional protocol), 120 kVp with filtered back projection; group B, 120 kVp with 50% ASIR-V; and group C, 100 kVp with 50% ASIR-V. All patients underwent scans in a 256-slice computed tomography (CT) scanner. Radiation dose (volume CT dose index), dose-length product, and effective dose, objective parameters such as arterial attenuation value, signal-to-noise ratio, contrast-to-noise ratio, and noise obtained at head, neck, and shoulder levels were compared among the groups. Subjective image quality was independently assessed by two radiologists, and interobserver reliability was assessed using kappa analysis.

RESULTS: The radiation dose in group C was the lowest (p < 0.01) with a 40% reduction in volume CT dose index, dose-length product, and effective dose values compared to group A, and group C showed higher arterial attenuation than either group A or B (p < 0.01). Additionally, signal-to-noise ratio and contrast-to-noise ratio were higher and noise was lower in groups B and C than group A. Group C had better subjective image quality than groups A and B (p < 0.05), and the interobserver reliability between the two radiologists was high (k = 0.783).

CONCLUSION: Compared to the conventional protocol, using 50% ASIR-V and the 100 kVp protocol during craniocervical computed tomographic angiography yields better objective and subjective image quality at lower radiation doses.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen CW, Chen PA, Chou CC, et al. Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose. Acad Radiol. 2018. PMID: 30195416. doi:10.1016/j.acra.2018.07.019