文献速递骨肌MR

T1加权MRI上肩部肌肉肌内脂肪浸润的量化:Goutallier分类系统的可行替代方案

Quantification of shoulder muscle intramuscular fatty infiltration on T1-weighted MRI: a viable alternative to the Goutallier classification system.
PubMed 文献 · Skeletal Radiol · 2018-09-10

前瞻性横断面研究对42块肩部肌肉行斜矢状面T1 MRI模糊C均值分割测量可见肌内脂肪面积百分比,并与六点Dixon MRI脂肪分数对照。模糊C均值分割与六点Dixon的组间信度分别为0.947和0.951,组内信度分别为0.871和0.979,两者强相关(单块肌肉r=0.850,p<0.001;按受试者r=0.977,p<0.002)。作者认为量化模糊C均值分割是半定量Goutallier分类系统的可行替代方案。

要点

  • 模糊C均值分割在T1加权序列上量化肩部肌内脂肪浸润的组间信度0.947、组内信度0.871。
  • 模糊C均值分割与六点Dixon脂肪分数强相关:单块肌肉r=0.850(p<0.001),按受试者r=0.977(p<0.002)。
  • 作者认为量化模糊C均值分割是半定量Goutallier分类系统的可行替代方案。

核心结论

  • T1加权序列上模糊C均值分割量化肌内脂肪浸润具有极好的信度,且与六点Dixon MRI脂肪分数强相关。
  • 量化模糊C均值分割是半定量Goutallier分类系统的可行替代方案。

研究设计与样本

  • 前瞻性横断面研究,对42块肩部肌肉行斜矢状面T1 MRI模糊C均值分割测量可见肌内脂肪面积百分比。
  • 以六点Dixon MRI脂肪分数图作为对照,评估组内与组间信度并行相关性分析。

诊断标准与关键数值

  • 模糊C均值分割量化可见肌内脂肪面积百分比的组间信度为0.947,六点Dixon脂肪分数的组间信度为0.951。
  • 模糊C均值分割量化可见肌内脂肪面积百分比的组内信度为0.871,六点Dixon脂肪分数的组内信度为0.979。
  • 模糊C均值分割与六点Dixon技术强相关:单块肌肉r=0.850,p<0.001;按受试者r=0.977,p<0.002。

临床应用与阅片要点

  • 原文结论认为量化模糊C均值分割是半定量Goutallier分类系统的可行替代方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Quantification of rotator cuff intramuscular fatty infiltration is important for clinical decision-making in patients with rotator cuff tear. The semi-quantitative Goutallier classification system is the most commonly used method, but has limited reliability. Therefore, we sought to test a freely available fuzzy C-means segmentation software program for reliability of the quantification of shoulder intramuscular fatty infiltration on T1-weighted MR images and for correlation with fat fraction by six-point Dixon MRI.

MATERIALS AND METHODS: We performed a prospective cross-sectional study to measure visible intramuscular fat area percentage on oblique sagittal T1 MR images by fuzzy C-means segmentation and fat fraction maps by six-point Dixon MRI for 42 shoulder muscles. Intra- and inter-observer reliability were determined. Correlative analysis for fuzzy C-means and six-point Dixon intramuscular fatty infiltration measures was also performed.

RESULTS: We found that inter-observer reliability for the quantification of visible intramuscular fat area percentage by fuzzy C-means segmentation and fat fraction by six-point Dixon MRI was 0.947 and 0.951 respectively. The intra-observer reliability for the quantification of visible intramuscular fat area percentage by fuzzy C-means segmentation and fat fraction by six-point Dixon MRI was 0.871 and 0.979 respectively. We found a strong correlation between fuzzy C-means segmentation and six-point Dixon techniques; r = 0.850, p < 0.001 by individual muscle; and r = 0.977, p < 0.002 by study subject.

CONCLUSION: Quantification of intramuscular fatty infiltration by fuzzy C-means segmentation on T1-weighted sequences demonstrates excellent reliability and strong correlation with fat fraction by six-point Dixon MRI. Quantitative fuzzy C-means segmentation is a viable alternative to the semi-quantitative Goutallier classification system.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Davis DL, Kesler T, Gilotra MN, et al. Quantification of shoulder muscle intramuscular fatty infiltration on T1-weighted MRI: a viable alternative to the Goutallier classification system. Skeletal Radiol. 2018. PMID: 30203182. doi:10.1007/s00256-018-3057-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。