文献速递骨肌US

健康成人股骨滑车软骨厚度髌上横切超声评估的可靠性

The Reliability of Suprapatellar Transverse Sonographic Assessment of Femoral Trochlear Cartilage Thickness in Healthy Adults.
PubMed 文献 · J Ultrasound Med · 2018-09-12

研究纳入77名健康成人,采用髌上横切超声在最多间隔7天的两次检查中测量滑车软骨厚度,组内相关系数为0.779-0.843,年轻成人中升至0.884-0.920,测量标准误为8.2%-8.3%,提示该方法重复性高;女性在所有部位软骨均较薄(P<.01),且为唯一显著独立预测因素。

要点

  • 髌上横切超声测量滑车软骨厚度的重测信度高(ICC 0.779-0.843),年轻成人更高(ICC 0.884-0.920)。
  • 测量标准误为8.2%-8.3%,最小真实差异为22.8%-23.1%,年轻成人分别降至5.4%-6.3%和14.9%-17.5%。
  • 女性在所有部位软骨厚度均较男性薄(P<.01),且为唯一显著独立预测因素。

核心结论

  • 髌上超声具有高组内信度和测量精度,是评估滑车软骨厚度的有前景方法;女性可能比年龄、体重和高体力活动频率等其他潜在膝骨关节炎危险因素对股骨软骨厚度影响更大。

研究设计与样本

  • 共77名健康志愿者(55名男性,22名女性),平均年龄43±18岁;采用静息髌上超声在最多间隔7天的两次独立检查中成像滑车软骨厚度;信度采用组内相关系数、Bland-Altman分析、测量标准误和最小真实差异评估。

诊断标准与关键数值

  • 所有部位重测一致性高(组内相关系数0.779-0.843),年轻成人中升至0.884-0.920;测量标准误所有部位为8.2%-8.3%,年轻成人降至5.4%-6.3%;最小真实差异全样本为22.8%-23.1%,仅年轻成人为14.9%-17.5%。

临床应用与阅片要点

  • 作者认为髌上超声是评估滑车软骨厚度的有前景方法;女性在所有部位软骨厚度均较薄(P<.01),且为所有模型中唯一显著独立预测因素(均P<.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the intrasession reliability of femoral cartilage thickness measurements using sonography and extend the pool of normative data for cartilage thickness measurements assessed by sonography.

METHODS: A total of 77 healthy participants (55 men, 22 women), with an average age of 43 ± 18 (mean ± standard deviation) years, volunteered. Resting suprapatellar sonography was used to image trochlear cartilage thickness on 2 separate occasions a maximum of 7 days apart. Reliability was evaluated with intraclass correlation coefficients, Bland-Altman analysis, standard error of measurement, and the smallest real difference. Normative data was assessed using linear, multiple regression models and independent group t tests.

RESULTS: The test-retest level of agreement at all locations was high (intraclass correlation coefficient, 0.779-0.843), which increased to high-very high in young adults (intraclass correlation coefficient, 0.884-0.920). The standard error of measurement was 8.2% to 8.3% at all locations and reduced further to 5.4% to 6.3% in younger adults. The smallest real difference was between 22.8% and 23.1% for the full sample and 14.9% and 17.5% in young adults only. Multiple regression analyses demonstrated that age, weight, female sex, and a high physical activity frequency could significantly predict cartilage thickness at all locations (P < .05); however, female sex was the only significant independent predictor in all models (all P < .01). Females also had thinner cartilage at all locations (P < .01).

CONCLUSION: Suprapatellar sonography demonstrates high intratester reliability and measurement precision and is a promising method to assess trochlear cartilage thickness. Being female may impact femoral cartilage thickness more than other potential risk factors for knee osteoarthritis such as age, weight, and high physical activity frequency.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Roberts HM, Moore JP, Thom JM, et al. The Reliability of Suprapatellar Transverse Sonographic Assessment of Femoral Trochlear Cartilage Thickness in Healthy Adults. J Ultrasound Med. 2018. PMID: 30208236. doi:10.1002/jum.14775

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。