高分辨率超声评估远端肱二头肌腱性复合体
研究通过50例冷冻尸体肘部解剖建立远端肱二头肌腱性复合体三个组成部分的形态学参考值,设计并验证高分辨率超声检查技术,并在44名健康志愿者中比较超声与解剖测量值。结果显示超声与解剖测量总体一致性良好(组内相关系数0.876,p<0.0001),除内部肱二头肌腱膜宽度外各测量值差异均<0.7 mm,外部肱二头肌腱膜形态学变异最大。
要点
- 高分辨率超声可系统评估远端肱二头肌腱性复合体,与解剖测量总体一致性良好(ICC 0.876)。
- 外部肱二头肌腱膜(lacertus fibrosus)形态学变异最大,阅片时需注意其宽度和厚度变化。
- 志愿者超声与解剖测量多数指标有显著差异,但总体幅度<0.7 mm,临床意义有限。
核心结论
- 采用本文提出的系统化方法,高分辨率超声可可靠评估远端肱二头肌腱性复合体的形态学;外部肱二头肌腱膜是形态学变异最大的结构。
研究设计与样本
- 研究分三部分:50例冷冻尸体供体肘部解剖获取形态学参考值并建立超声标志;11例冷冻尸体供体肘部进行一对一超声/解剖验证;44名健康志愿者行系统超声检查并与解剖参考值比较。
诊断标准与关键数值
- 解剖参考均值:内部肱二头肌腱膜宽度39.61 mm(标准差10.02)、厚度0.75 mm(标准差0.24);远端肱二头肌腱宽度8.38 mm(标准差1.87)、厚度2.73 mm(标准差0.69);外部肱二头肌腱膜宽度11.17 mm(标准差5.84)、厚度0.85 mm(标准差0.28)。超声/解剖一对一相关性总体良好(组内相关系数0.876,p<0.0001)。志愿者超声与解剖测量比较,除内部肱二头肌腱膜宽度外所有测量值均有显著差异,但差异总体幅度<0.7 mm。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To establish a high-resolution US technique that enables a systematic morphometric examination of the three components that form the distal biceps brachii tendinous complex; the internal bicipital aponeurosis, the distal biceps brachii tendon and the external bicipital aponeurosis (also known as lacertus fibrosus).
MATERIALS AND METHODS: Fifty cryopreserved cadaver body donor elbows were dissected to obtain morphometric reference values and to establish reliable landmarks for the US examination. Then, a systematic US technique was designed and validated by a one-to-one US/dissection analysis of 11 cryopreserved cadaver body donor elbows. Finally, the systematic US technique was carried out in 44 healthy volunteers and morphometric parameters were compared to those obtained in the first part of the study.
RESULTS: Mean dissection reference values: internal bicipital aponeurosis width 39.61 mm (10.02 SD) and thickness 0.75 mm (0.24 SD), distal biceps brachii tendon width 8.38 mm (1.87 SD) and thickness 2.73 mm (0.69 SD), external bicipital aponeurosis width 11.17 mm (5.84 SD) and thickness 0.85 mm (0.28 SD). One-to-one US/dissection correlation was overall good (intraclass correlation coefficient 0.876, p < 0.0001). When comparing volunteer US/dissection measurements, significant differences were encountered in all measures except for internal bicipital aponeurosis width. However, the overall magnitude of such significant differences was < 0.7 mm.
CONCLUSIONS: Using the systematics hereby proposed, high-resolution US is reliable for the morphometric assessment of the distal biceps brachii tendinous complex. The external bicipital aponeurosis is morphometrically the most variable structure.
引用
- Blasi M, De la Fuente J, Pérez-Bellmunt A, et al. High-resolution ultrasound in the assessment of the distal biceps brachii tendinous complex. Skeletal Radiol. 2018. PMID: 30187110. doi:10.1007/s00256-018-3043-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。