锥光束乳腺CT与乳腺X线摄影的可靠性比较:参照第五版BI-RADS图集的乳腺密度评估

A Reliability Comparison of Cone-Beam Breast Computed Tomography and Mammography: Breast Density Assessment Referring to the Fifth Edition of the BI-RADS Atlas.
PubMed 文献 · Acad Radiol · 2018-09-14

研究纳入130例女性患者,由5名放射科医生参照第五版BI-RADS图集在双视角乳腺X线摄影和锥光束乳腺CT(CBBCT)图像上评估乳腺密度,其中3名医生在超过1个月后重复评估。CBBCT的读者间和读者内一致性均高于乳腺X线摄影,两种检查方式间的一致性为基本一致,且经验更丰富的读者更常报告较高密度类别。

要点

  • CBBCT评估乳腺密度的读者间一致性为0.781,高于乳腺X线摄影的0.744。
  • CBBCT的读者内可靠性为0.856,高于乳腺X线摄影的0.786。
  • 经验更丰富的读者更常报告较高的乳腺密度类别。

核心结论

  • 与乳腺X线摄影相比,CBBCT在乳腺密度评估中表现出同等的能力和更好的一致性,可能成为常规诊断和乳腺癌筛查中评估乳腺密度和乳腺癌风险的有效检查方式。

研究设计与样本

  • 研究对130例女性患者进行乳腺密度评估,由5名放射科医生参照第五版BI-RADS图集在双视角乳腺X线摄影和CBBCT图像上完成,其中3名不同经验的医生在初次评估超过1个月后重复评估,采用Cohen加权Kappa统计量和组内相关系数比较读者间和读者内一致性。

诊断标准与关键数值

  • CBBCT图像的读者间一致性为0.781,乳腺X线摄影为0.744,均显示中等一致性;CBBCT的读者内可靠性为0.856,乳腺X线摄影为0.786;基于多数报告,两种检查方式间的一致性为基本一致。

临床应用与阅片要点

  • 作者认为CBBCT可能成为常规诊断和乳腺癌筛查中评估乳腺密度和乳腺癌风险的有效检查方式。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the reliability of cone-beam breast computed tomography (CBBCT) in visual assessment of breast density referring to the fifth edition of the Breast Imaging Reporting and Data System compared to digital mammography.

MATERIALS AND METHODS: Breast density assessments of 130 female patients were performed by five radiologists referring to the fifth edition of Breast Imaging Reporting and Data System atlas both on two-view mammograms and CBBCT images. Assessments were repeated by three radiologists with different experience more than 1 month after the initial evaluation. The inter- and intrareader agreements were compared by using the Cohen's weighted Kappa statistic and intraclass correlation coefficient. Weighted Kappa statistic was also used to analyze the agreement between CBBCT images and mammograms. The influence of radiologist experience for breast density assessment was analyzed using a chi-square test.

RESULTS: For CBBCT images, the inter-reader agreement was 0.781, whereas the agreement on mammograms was 0.744, both demonstrating moderate agreement. The level of intrareader reliability was higher on the CBBCT images than mammograms for breast density evaluation, 0.856 versus 0.786. Based on the majority report, the agreement between these two modalities was on substantial agreement degree. There was a statistically significant difference among radiologists with different levels of experience, and higher density categories were reported more often by experienced reader.

CONCLUSION: CBBCT showed equal aptitude and better agreement for the breast density evaluation compared to mammography. CBBCT could be an effective modality for breast density assessment and breast cancer risk evaluation in routine diagnosis and breast cancer screening.

来源:Acad Radiol,查看原文。版权归原作者所有。