利用深度卷积神经网络测定乳腺X线摄影乳腺密度
本研究基于本院影像归档与通信系统中5221例患者共20578幅乳腺X线摄影单视图,训练并验证了一个含11个卷积层和3个全连接层的深度卷积神经网络,按ACR BI-RADS密度a-d自动分类乳腺密度;模型与放射学报告及两名阅片者共识决策对比,在区分致密型与脂肪型乳腺时一致性较高。
要点
- 模型与放射学报告总体一致率MLO为71.7%、CC为71.0%,区分致密与脂肪乳腺时升至MLO 88.6%、CC 89.9%。
- 与两名阅片者共识决策对比,MLO模型一致率92.2%,右CC模型87.4%,区分脂肪型与致密型达MLO 99%、CC 96%。
- 验证集准确率MLO为90.9%、CC为90.1%,最优训练轮次MLO为91、CC为94。
核心结论
- 深度卷积神经网络可基于ACR BI-RADS系统对乳腺密度进行准确分类,该技术可能实现准确、标准化且不依赖观察者的乳腺X线摄影密度评估。
研究设计与样本
- 研究论文;从本院影像归档与通信系统下载5221例患者(58.3 ± 11.5岁)的20578幅乳腺X线摄影单视图,按对应放射学报告提供的ACR密度(a-d)自动排序,训练并验证含11个卷积层和3个全连接层的深度卷积神经网络,最终在两个独立测试数据集上分别与放射学报告及两名阅片者共识决策对比。
诊断标准与关键数值
- 模型与放射学报告一致率:测试集一(850幅MLO、880幅CC)MLO为71.7%、CC为71.0%;区分致密与脂肪乳腺时MLO为88.6%、CC为89.9%。与两名阅片者共识决策一致率:测试集二(200幅乳腺X线摄影)MLO模型92.2%、右CC模型87.4%;区分脂肪型(ACR A/B)与致密型(ACR C/D)时MLO达99%、CC达96%。验证集准确率MLO为90.9%、CC为90.1%;最优训练轮次MLO为91、CC为94。
临床应用与阅片要点
- 作者认为,由深度卷积神经网络对乳腺X线摄影进行标准化分类可能减少被错误分类的乳腺密度,从而有助于更准确评估个体患者的乳腺癌风险,并更可靠地决定是否建议补充超声检查。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: High breast density is a risk factor for breast cancer. The aim of this study was to develop a deep convolutional neural network (dCNN) for the automatic classification of breast density based on the mammographic appearance of the tissue according to the American College of Radiology Breast Imaging Reporting and Data System (ACR BI-RADS) Atlas.
METHODS: In this study, 20,578 mammography single views from 5221 different patients (58.3 ± 11.5 years) were downloaded from the picture archiving and communications system of our institution and automatically sorted according to the ACR density (a-d) provided by the corresponding radiological reports. A dCNN with 11 convolutional layers and 3 fully connected layers was trained and validated on an augmented dataset. The model was finally tested on two different datasets against: i) the radiological reports and ii) the consensus decision of two human readers. None of the test datasets was part of the dataset used for the training and validation of the algorithm.
RESULTS: The optimal number of epochs was 91 for medio-lateral oblique (MLO) projections and 94 for cranio-caudal projections (CC), respectively. Accuracy for MLO projections obtained on the validation dataset was 90.9% (CC: 90.1%). Tested on the first test dataset of mammographies (850 MLO and 880 CC), the algorithm showed an accordance with the corresponding radiological reports of 71.7% for MLO and of 71.0% for CC. The agreement with the radiological reports improved in the differentiation between dense and fatty breast for both projections (MLO = 88.6% and CC = 89.9%). In the second test dataset of 200 mammographies, a good accordance was found between the consensus decision of the two readers on both, the MLO-model (92.2%) and the right craniocaudal-model (87.4%). In the differentiation between fatty (ACR A/B) and dense breasts (ACR C/D), the agreement reached 99% for the MLO and 96% for the CC projections, respectively.
CONCLUSIONS: The dCNN allows for accurate classification of breast density based on the ACR BI-RADS system. The proposed technique may allow accurate, standardized, and observer independent breast density evaluation of mammographies.
ADVANCES IN KNOWLEDGE: Standardized classification of mammographies by a dCNN could lead to a reduction of falsely classified breast densities, thereby allowing for a more accurate breast cancer risk assessment for the individual patient and a more reliable decision, whether additional ultrasound is recommended.
引用
- Ciritsis A, Rossi C, Vittoria De Martini I, et al. Determination of mammographic breast density using a deep convolutional neural network. Br J Radiol. 2018. PMID: 30209957. doi:10.1259/bjr.20180691
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。