全子宫容积CT灌注成像特征及血供影响因素:宫颈鳞癌的初步研究
本研究对43例活检确诊的宫颈鳞癌患者行640层CT全子宫容积灌注成像,其中24例同时行MR检查。结果显示vCTP测量肿瘤大小与MR无显著差异,灌注参数测量稳定性良好(组内相关系数0.818-0.945);宫颈鳞癌动脉血流量显著高于正常子宫体,血容量与渗透性表面无统计学差异;动脉血流量和渗透性表面与患者年龄呈负相关。
要点
- vCTP可准确显示宫颈鳞癌大小,与MR参考标准无显著差异。
- 宫颈鳞癌动脉血流量显著高于正常子宫体,血容量与渗透性表面无统计学差异。
- 动脉血流量和渗透性表面与患者年龄呈负相关,老年女性高血供趋势减弱。
核心结论
- vCTP以MR为参考标准可准确显示宫颈鳞癌大小,灌注参数测量稳定性良好;宫颈鳞癌呈富血供,但该趋势在老年女性中较弱。
研究设计与样本
- 前瞻性初步研究,纳入43例活检确诊的宫颈鳞癌患者,采用640层CT系统行全子宫容积CT灌注成像,其中24例同期行MR检查;由两名放射科医师测量灌注参数并以组内相关系数评估观察者间信度。
关键影像表现/征象
- vCTP与MR测量的肿瘤大小无显著差异。
- 宫颈鳞癌动脉血流量值显著高于正常子宫体。
- 宫颈鳞癌血容量和渗透性表面值与正常子宫体相比无统计学差异。
诊断标准与关键数值
- 各灌注参数观察者间组内相关系数为0.818-0.945。
- 不同FIGO分期及病理分级间宫颈鳞癌动脉血流量值无显著差异。
- 宫颈鳞癌动脉血流量和渗透性表面值与患者年龄呈负相关。
临床应用与阅片要点
- vCTP可用于评估宫颈鳞癌大小及血供特征,灌注参数测量稳定性好。
- 阅片时注意宫颈鳞癌动脉血流量高于正常子宫体,但血容量和渗透性表面与正常子宫体无统计学差异。
- 患者年龄可能影响肿瘤血供评估,老年女性高血供趋势较弱。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To explore the imaging features of whole uterus volume CT perfusion (vCTP) and the influence factors of blood supply in cervical squamous carcinoma (CSC).
MATERIALS AND METHODS: vCTP was performed on a 640-slice computed tomography system in 43 patients with CSC diagnosed by biopsy, and 24 cases of them underwent magnetic resonance imaging. The size of the tumor was measured on vCTP and magnetic resonance (MR) images. Perfusion parameters, including arterial blood flow (AF), blood volume, and permeability surface (PS), were measured by two radiologists, using interclass correlation coefficient to evaluate the interobserver reliability. The difference of tumor size and perfusion data was analyzed by paired t test and rank sum test. The correlation of perfusion parameters with some factors was analyzed by Pearson or Spearman correlation analysis.
RESULTS: Tumor sizes were not significantly different between vCTP and MR images. The interclass correlation coefficient of each parameter was 0.818-0.945. The AF value of CSC was significantly higher than normal uterine body, and the blood volume and PS values of CSC were not statistically different compared with those of normal uterine body. There was no significant difference in AF value of CSC among different FIGO stages and pathological grades. The AF and PS values of CSC were negatively correlated with the age of the patients.
CONCLUSION: The vCTP could accurately shows the size of the CSC with use of MR as the reference standard, and its perfusion parameters have good measurement stability; the CSC was hypervascular, but this trend was less pronounced in older women.
引用
- Yue D, Tong DR, Fei Fei W, et al. Imaging Features of the Whole Uterus Volume CT Perfusion and Influence Factors of Blood Supply: A Primary Study in Patients with Cervical Squamous Carcinoma. Acad Radiol. 2018. PMID: 30201435. doi:10.1016/j.acra.2018.07.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。