快速千伏切换双能CT与实验室结石分析对照表征肾结石成分:一项先导研究
该先导研究前瞻性纳入39例拟行内镜取石术患者,术前用单源快速千伏切换双能CT(DECT)测量有效原子序数判断结石成分,以术后红外光谱结石分析为参考标准。DECT检出尿酸结石敏感度88.9%、特异度100%、准确率97.4%;含碘图可弥补Zeff单独判断混合成分中尿酸结石的不足,使所有含尿酸结石均可被DECT确定。
要点
- DECT检出尿酸结石敏感度88.9%、特异度100%、准确率97.4%。
- 单一成分结石中尿酸结石DECT正确表征率100%(8/8)。
- Zeff单独判断混合成分中尿酸结石效果欠佳,加碘图可弥补。
核心结论
- DECT在表征尿酸结石成分方面具有极好的准确率。
- 加用碘图后,所有含尿酸结石均可由DECT确定。
研究设计与样本
- 前瞻性先导研究,2015年6月至2016年1月在一家三级转诊医院连续纳入拟行内镜肾结石手术的同意患者39例。
- 术前采用单源快速千伏切换双能CT扫描,依据有效原子序数测量判定结石成分。
- 以术后红外光谱结石分析为标准参考,比较DECT的结石成分结果。
诊断标准与关键数值
- DECT检出尿酸结石:敏感度88.9%、特异度100%、阳性预测值100%、阴性预测值96.8%、准确率97.4%。
- 非增强CT检出尿酸结石:敏感度88.9%、特异度96.7%、阳性预测值88.9%、阴性预测值96.7%、准确率94.8%。
- 39个样本中21个(54%)为单一成分,18个(46%)为混合成分。
- 单一成分结石中,DECT对尿酸结石正确表征率为100%(8/8)。
临床应用与阅片要点
- DECT依据有效原子序数测量可高准确率识别尿酸结石。
- 混合成分中含尿酸结石仅用Zeff判断效果欠佳,碘图可弥补该不足。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis.
METHODS: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference.
RESULTS: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Zeff alone, iodine imaging can compensated this fault.
CONCLUSIONS: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.