肝动脉栓塞术中自动锥形束CT血管识别软件与数字减影血管造影的比较:辐射剂量、对比剂用量、处理时间及操作者观点评估
回顾性评估2014年2月至8月连续34例肝动脉栓塞术中的30例,比较自动血管测绘软件处理的动脉锥形束CT与数字减影血管造影。软件在13例(43%)中识别出至少一条额外栓塞靶血管,11例(37%)栓塞方案被修改,83%病例操作信心增加,50%病例减少DSA采集次数;锥形束CT占辐射剂量11%、对比剂用量18%。
要点
- 自动血管测绘软件在43%的肝动脉栓塞术中识别出至少一条额外栓塞靶血管。
- 37%的病例基于软件结果修改了栓塞方案,83%病例操作者信心增加。
- 动脉锥形束CT仅占辐射剂量11%和对比剂用量18%,采集与处理时间分别为4分53秒和3分45秒。
核心结论
- 医师报告在肝动脉栓塞术中使用自动血管测绘软件可提高肿瘤供血血管检出率和术中信心,对辐射剂量、对比剂用量和手术时间无实质性影响。
研究设计与样本
- 经机构审查委员会批准并豁免知情同意的回顾性研究,纳入2014年2月至2014年8月连续34例肝动脉栓塞术中的30例,比较动脉锥形束CT经自动血管测绘软件处理与数字减影血管造影。
诊断标准与关键数值
- 自动血管测绘软件在13例(43%,95%CI:26-61%)中识别出至少一条额外栓塞靶血管。
- 基于自动血管测绘软件,11例(37%,95%CI:19-54%)的栓塞方案被修改。
- 放射科医师报告自动血管测绘软件使25例(83%,95%CI:70-97%)操作信心增加,使15例(50%,95%CI:32-68%)DSA采集次数减少。
- 动脉锥形束CT采集和处理时间平均分别为4分53秒和3分45秒,占辐射剂量的11%和对比剂用量的18%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate arterial cone-beam computed tomography (A-CBCT) automated analysis software for identification of vessels supplying tumours during transarterial hepatic embolisation (TAE).
MATERIALS AND METHODS: This study was approved by the institutional review board, with waiver of consent. Consecutive TAE procedures using arterial mapping software (AMS), and performed between February 2014 and August 2014, were reviewed. Hepatic arteries were imaged using digital subtraction angiography (DSA) as well as A-CBCT processed with AMS. Interventional radiologists reported1 potential embolisation target vessels computed using AMS versus DSA alone,2 modification of the embolisation plan based on AMS, and3 operator confidence related to technical success. Imaging set-up, processing time, radiation dose, and contrast media volume were recorded.
RESULTS: Thirty of 34 consecutive procedures were evaluated retrospectively. At least one additional embolisation target vessel was identified using AMS in 13 procedures (43%, 95% confidence interval [CI]: 26-61%) and embolisation plan modified in 11 (37%, 95% CI: 19-54%). Radiologists reported AMS increased operator confidence and reduced the number of DSA acquisitions in 25 (83%, 95% CI: 70-97%) and 15 cases (50%, 95% CI: 32-68%), respectively. The average A-CBCT acquisition and processing time was 4 minutes 53 seconds and 3 minutes 45 seconds, respectively. A-CBCT contributed to 11% of the radiation dose and 18% of the contrast media volume.
CONCLUSION: Physicians report increased tumour supplying vessel detection and intraprocedural confidence using AMS during TAE without substantial impact on radiation dose, contrast media volume, and procedure time.
引用
- Durack JC, Brown KT, Avignon G, et al. Assessment of automated cone-beam CT vessel identification software during transarterial hepatic embolisation: radiation dose, contrast medium volume, processing time, and operator perspectives compared to digital subtraction angiography. Clin Radiol. 2018. PMID: 30220595. doi:10.1016/j.crad.2018.08.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。