文献速递腹部介入CTUS

计算机断层扫描或超声造影用于射波刀治疗后肝转移瘤随访:一项前瞻性先导研究

Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study.
PubMed 文献 · J Ultrasound Med · 2018-09-04

该前瞻性先导研究连续纳入24例患者,共检出并治疗40个肝继发性病灶,在射波刀治疗后1个月和2个月行超声造影(CEUS)并与增强CT(CECT)对照。3名操作者评估CEUS图像,与CECT的模态间一致率Cohen κ分别为1.00、0.881和0.767,多变量分析模态间一致值为ι=0.841。作者认为CEUS与CECT在评估肝转移瘤射波刀治疗后局部疾病稳定或进展方面诊断一致性极好,CEUS可能在这些患者的监测中发挥重要作用。

要点

  • 射波刀治疗后1个月和2个月行CEUS,与CECT评估肝转移瘤局部稳定或进展的模态间一致率κ为1.00、0.881和0.767。
  • 多变量分析的模态间一致值为ι=0.841,提示CEUS与CECT诊断一致性几乎完美。
  • 作者认为CEUS因高准确性和可重复性可能在这些患者的监测中发挥重要作用,从而减少对CECT的需求。

核心结论

  • 这项先导研究发现,CEUS与CECT在评估肝转移瘤射波刀治疗后局部疾病稳定或进展方面诊断一致性极好;这些发现提示CEUS因高准确性和可重复性可能在这些患者的监测中发挥重要作用,从而减少对CECT的需求。

研究设计与样本

  • 前瞻性先导研究,连续纳入24例患者,检出并治疗40个肝继发性病灶;所有患者在射波刀治疗后1个月和2个月接受CEUS;3名不同操作者评估CEUS图像并与CECT进行模态间一致率分析;采用Cohen κ系数及依据Janson和Olsson(Educ Psychol Meas 2001; 61:277-289)方法的多变量分析评估模态间一致性。

诊断标准与关键数值

  • 3名操作者评估CEUS与CECT的模态间一致率Cohen κ分别为1.00、0.881和0.767。
  • 模态间一致率的多变量分析显示ι=0.841,为几乎完美的一致值。

临床应用与阅片要点

  • 作者认为CEUS因高准确性和可重复性可能在这些患者的监测中发挥重要作用,从而减少对CECT的需求。

局限性

  • 原文标题与结论均称本研究为先导研究(pilot study),原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Contrast-enhanced ultrasonography (CEUS) allows the study of vascularization of secondary liver lesions. The Cyberknife (Accuray, Inc, Sunnyvale, CA) is a therapeutic method that allows a tumor target to be subjected to a high radiant dose gradient. This prospective pilot study aimed to demonstrate the concordance of CEUS versus contrast-enhanced computed tomography (CECT) in determining the stability or disease progression of secondary liver lesions after treatment with the Cyberknife.

METHODS: Twenty-four patients were consecutively enrolled, and 3 different operators evaluated the CEUS images and the intermodality concordance with CECT. All patients received CEUS at 1 and 2 months after the Cyberknife therapy. The intermodality agreement was evaluated by the Cohen κ coefficient and a multivariate analysis according to the method of Janson and Olsson (Educ Psychol Meas 2001; 61:277-289).

RESULTS: Forty secondary liver lesions were detected and treated. Forty-one CECT and 51 CEUS examinations were performed without any adverse events in the 24 patients. The intermodality agreement rates, calculated for the operators as Cohen κ values, were κ = 1.00, 0.881, and 0.767, respectively. The multivariate analysis of intermodality agreement showed an almost perfect value (ι = 0.841).

CONCLUSIONS: This pilot study found excellent diagnostic correspondence between CEUS and CECT in the evaluation of local disease stability or progression after Cyberknife therapy in liver metastases. These findings suggest that CEUS could play an important role in the surveillance of these patients because of its high accuracy and reproducibility, thus reducing the need for CECT.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Marsico M, Gabbani T, Lunardi S, et al. Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study. J Ultrasound Med. 2018. PMID: 30182490. doi:10.1002/jum.14734

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。