基于人工智能的腹部CT急性病变检测软件评估:迈向常规CT检查的自动化工作列表优先级排序
本研究使用深度学习算法在100例含游离气体、游离液体或脂肪条索的连续腹部CT和100例对照中检测急性病变,以临床批准报告为标准,算法总体敏感度93%、特异度97%,提示可用于腹部CT急性病变的工作流程优先级排序。
要点
- 算法检测腹部急性病变总体敏感度93%(91/98)、特异度97%(93/96)。
- 腹腔游离气体敏感度92%(54/59)、特异度93%(39/42)。
- 游离液体敏感度85%(68/80)、特异度95%(20/21);脂肪条索敏感度81%(42/50)、特异度98%(48/49)。
核心结论
- 算法自主检测腹部急性病理表现具有较高诊断性能,可引导放射工作流程优先处理含急性情况的腹部CT检查。
研究设计与样本
- 回顾性诊断性能研究,纳入100例至少含游离气体、游离液体或脂肪条索之一的连续腹部CT和100例无这些表现的对照,使用卷积神经网络算法分析,由1年腹部影像经验的放射科医师在不知道图像表现的情况下通过视觉确认并与临床批准书面报告比较作为参考标准进行验证。
诊断标准与关键数值
- 总体急性腹部病变检测敏感度93%(91/98,7例假阴性)、特异度97%(93/96,3例假阳性)。
- 腹腔游离气体检测敏感度92%(54/59)、特异度93%(39/42)。
- 游离液体检测敏感度85%(68/80)、特异度95%(20/21)。
- 脂肪条索检测敏感度81%(42/50)、特异度98%(48/49)。
临床应用与阅片要点
- 假阳性结果源于条纹伪影、部分容积效应和憩室误识别(各n=1)。
- 全部病例纳入最终分析,仅整数据集无法被检测软件处理的病例除外。
局限性
- 6例因从本地PACS提取DICOM数据集时出现技术问题而被排除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to test the diagnostic performance of a deep learning-based triage system for the detection of acute findings in abdominal computed tomography (CT) examinations.
MATERIALS AND METHODS: Using a RIS/PACS (Radiology Information System/Picture Archiving and Communication System) search engine, we obtained 100 consecutive abdominal CTs with at least one of the following findings: free-gas, free-fluid, or fat-stranding and 100 control cases with absence of these findings. The CT data were analyzed using a convolutional neural network algorithm previously trained for detection of these findings on an independent sample. The validation of the results was performed on a Web-based feedback system by a radiologist with 1 year of experience in abdominal imaging without prior knowledge of image findings through both visual confirmation and comparison with the clinically approved, written report as the standard of reference. All cases were included in the final analysis, except those in which the whole dataset could not be processed by the detection software. Measures of diagnostic accuracy were then calculated.
RESULTS: A total of 194 cases were included in the analysis, 6 excluded because of technical problems during the extraction of the DICOM datasets from the local PACS. Overall, the algorithm achieved a 93% sensitivity (91/98, 7 false-negative) and 97% specificity (93/96, 3 false-positive) in the detection of acute abdominal findings. Intra-abdominal free gas was detected with a 92% sensitivity (54/59) and 93% specificity (39/42), free fluid with a 85% sensitivity (68/80) and 95% specificity (20/21), and fat stranding with a 81% sensitivity (42/50) and 98% specificity (48/49). False-positive results were due to streak artifacts, partial volume effects, and a misidentification of a diverticulum (each n = 1).
CONCLUSIONS: The algorithm's autonomous detection of acute pathological abdominal findings demonstrated a high diagnostic performance, enabling guidance of the radiology workflow toward prioritization of abdominal CT examinations with acute conditions.
引用
- Winkel DJ, Heye T, Weikert TJ, et al. Evaluation of an AI-Based Detection Software for Acute Findings in Abdominal Computed Tomography Scans: Toward an Automated Work List Prioritization of Routine CT Examinations. Invest Radiol. 2019. PMID: 30199417. doi:10.1097/RLI.0000000000000509
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。