肝脏和脾脏的声辐射力成像能否预测胃食管静脉曲张的存在?
本研究纳入58例接受6个月一次超声监测肝癌且6个月内将行食管胃十二指肠镜(OGD)的肝硬化患者,在常规超声时用声辐射力成像(ARFI)评估肝脾,并收集血小板计数、脾脏大小和瞬时弹性成像参数。14例(24%)存在胃食管静脉曲张(GOVs),有无GOVs者肝脏和脾脏ARFI测值差异无统计学意义,血小板/脾脏比值在多因素分析中与GOVs存在相关;结论为ARFI尚不能替代OGD预测该人群GOVs。
要点
- 有无胃食管静脉曲张的肝硬化患者肝脾ARFI测值差异无统计学意义(肝脏OR=1.75,95%CI 0.82–3.91;脾脏OR=1.12,95%CI 0.33–3.97)。
- 血小板/脾脏比值在多因素分析中与胃食管静脉曲张存在与否相关(OR=0.32,95%CI 0.008–0.91)。
- ARFI尚不能替代食管胃十二指肠镜预测该组患者的胃食管静脉曲张。
核心结论
- 有胃食管静脉曲张者肝脏和脾脏ARFI测值总体更高,但差异无统计学意义,ARFI尚不能替代OGD预测该组患者的GOVs。
研究设计与样本
- 研究纳入58例接受6个月一次超声监测肝癌且6个月内将行OGD的肝硬化患者,在常规超声时用ARFI评估肝脾,并收集血小板计数、脾脏大小和瞬时弹性成像测量值,采用Logistic回归分析变量与静脉曲张存在与否的关联。
诊断标准与关键数值
- 有GOVs者肝脏ARFI测值为2.39,无GOVs者为2.13,差异无统计学意义(OR=1.75,95%CI 0.82–3.91)。
- 有GOVs者脾脏ARFI测值为2.89,无GOVs者为2.82,差异无统计学意义(OR=1.12,95%CI 0.33–3.97)。
- 血小板/脾脏比值在多因素分析中与GOVs存在与否相关(OR=0.32,95%CI 0.008–0.91)。
临床应用与阅片要点
- 在肝硬化患者超声监测中,肝脾ARFI测值高低不能单独用于判断有无胃食管静脉曲张。
- 血小板/脾脏比值与胃食管静脉曲张存在相关,但ARFI尚不能替代OGD进行预测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To determine whether acoustic radiation force imaging (ARFI) of the liver/spleen could be used in patients with cirrhosis to predict the presence of gastroesophageal varices (GOVs).
MATERIALS AND METHODS: Fifty-eight patients with cirrhosis who were undergoing 6-monthly ultrasound examinations for hepatoma surveillance and who were due to have oesophagogastroduodenoscopy (OGD) within 6 months of their ultrasound were recruited. During routine ultrasound, the patient's liver and spleen were also assessed using ARFI. Other clinical parameters (platelet count, spleen size, and transient elastography measurements) were also collected. Logistic regression was used to determine which variables were significantly associated with presence or absence of varices univariably and multivariably RESULTS: Fourteen patients (24%) had GOVs. Patients with GOVs had higher ARFI measurements in the liver and spleen than patients without GOVs (liver: 2.39 versus 2.13, spleen: 2.89 versus 2.82), but these results were not statistically significant (odds ratio=1.75, 95% confidence interval [CI]=0.82, 3.91 and odds ratio=1.12, 95% CI=0.33, 3.97, respectively). The platelet/splenic ratio, in comparison, was associated with the presence or absence of GOVs in multivariate analysis (odds ratio=0.32, 95% CI=0.008, 0.91).
CONCLUSION: Although patients with GOVs had overall higher ARFI liver and spleen results, this was not statistically significant. As such, ARFI cannot yet replace OGD in predicting GOVs in this patient group.
引用
- Wiles R, Patanwala I, Hankinson B, et al. Can acoustic radiation force imaging of the liver and spleen predict the presence of gastroesophageal varices? Clin Radiol. 2018. PMID: 30245070. doi:10.1016/j.crad.2018.07.199
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。