磁化传递成像与多梯度回波磁共振成像术前评估胰腺纤维化与脂肪沉积:磁共振表现与组织学的相关性
本研究前瞻性纳入24例胰十二指肠切除术前患者,于3 T MRI行定量磁化传递成像和多梯度回波成像,测量胰尾和切缘的磁化传递率(MTR)与质子密度脂肪分数(PDFF),并与组织病理学分级对照。结果显示晚期纤维化(F3)组MTR显著高于F1组,晚期脂肪沉积(L2-L3)组PDFF显著高于L1组,MTR与纤维化分级、PDFF与脂肪沉积分级均呈中度显著正相关。
要点
- MTR在切缘和胰尾均与纤维化分级呈中度正相关(r=0.532、0.554)。
- PDFF在切缘和胰尾均与脂肪沉积分级呈中度正相关(r=0.668、0.707)。
- 胰腺腺癌组织MTR显著高于胰腺实质(44±5.5 vs 36.0±4.4和37.4±5.4,P=0.004)。
核心结论
- 胰腺多参数MRI包括MTR和PDFF图可能提供术前无创的胰腺纤维化和脂肪沉积定量信息。
研究设计与样本
- 前瞻性研究,24例患者(年龄68±8岁,男性16例)于胰十二指肠切除术前1天在3 T MRI行定量MT成像(二维梯度回波序列,加与不加MT预脉冲)和多梯度回波成像,以组织病理学为参考标准。
关键影像表现/征象
- 晚期纤维化(F3)患者切缘MTR为38±4,高于F1组的32.3±1.6(P=0.018)。
- 晚期纤维化(F3)患者胰尾MTR为39.7±5.5,高于F1组的31.2±1.7(P=0.001)。
- 晚期脂肪沉积(L2-L3)胰腺实质PDFF显著高于脂肪沉积L1级(切缘P=0.002,胰尾P=0.001)。
- 胰腺腺癌组织MTR为44±5.5,显著高于胰腺实质的36.0±4.4和37.4±5.4(P=0.004)。
诊断标准与关键数值
- 组织病理学胰腺纤维化分级:轻度、中度、重度(F1-F3)。
- 组织病理学脂肪沉积分级:0%-10%、11%-30%、大于30%脂肪沉积(L1-L3)。
- MTR与纤维化分级在切缘和胰尾的Spearman相关系数分别为r=0.532(P=0.011)和r=0.554(P=0.008)。
- PDFF与脂肪沉积分级在切缘和胰尾的相关系数分别为r=0.668和r=0.707(均P<0.001)。
临床应用与阅片要点
- MTR和PDFF图可能为术前无创定量评估胰腺纤维化和脂肪沉积提供信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to evaluate the diagnostic performance of magnetization transfer (MT) imaging and multigradient echo magnetic resonance imaging (MRI) to quantify pancreatic fibrosis and lipomatosis in patients before pancreatoduodenectomy for postoperative risk stratification with histopathology as the reference standard.
MATERIALS AND METHODS: Twenty-four patients (age, 68 ± 8 years, 16 males) prospectively underwent quantitative MT imaging using a 2-dimensional gradient echo sequence with and without MT prepulse and multigradient echo imaging on a 3 T MRI 1 day before pancreatoduodenectomy due to adenocarcinoma of the pancreatic head region (n = 20), neuroendocrine tumor (n = 3), or intraductal papillary mucinous neoplasm (n = 1). Magnetization transfer ratio (MTR) and proton density fat fraction (PDFF) were measured in pancreatic tail (PT) and at the resection margin (RM). Histopathologically, pancreatic fibrosis was graded as mild, moderate, or severe (F1-F3), lipomatosis was graded as 0% to 10%, 11% to 30%, and greater than 30% fat deposition (L1-L3). In addition, MTR and histopathologic fibrosis was assessed in pancreatic adenocarcinoma. Mann-Whitney U test and Spearman correlation were used.
RESULTS: Patients with advanced pancreatic fibrosis (F3) showed a significantly higher MTR compared with the F1 group at the RM and PT (38 ± 4 vs 32.3 ± 1.6, P = 0.018 and 39.7 ± 5.5 vs 31.2 ± 1.7, P = 0.001). Spearman correlation coefficient of MTR and fibrosis grade was r = 0.532 (P = 0.011) and 0.554 (P = 0.008), respectively. Pancreatic parenchyma with advanced fat deposition (L2-L3) showed significantly higher PDFF compared with lipomatosis grade L1 (RM: P = 0.002 and PT: P = 0.001). Proton density fat fraction of pancreatic parenchyma exhibited a moderate and significant correlation with histopathologic lipomatosis grade (RM: r = 0.668 and PT: r = 0.707, P < 0.001). Magnetization transfer ratio was significantly higher in pancreatic adenocarcinoma compared with pancreatic parenchyma (44 ± 5.5 vs 36.0 ± 4.4 and 37.4 ± 5.4, P = 0.004).
CONCLUSIONS: Multiparametric MRI of the pancreas including MTR and PDFF maps may provide quantitative and noninvasive information on pancreatic fibrosis and lipomatosis before surgery.
引用
- Schawkat K, Eshmuminov D, Lenggenhager D, et al. Preoperative Evaluation of Pancreatic Fibrosis and Lipomatosis: Correlation of Magnetic Resonance Findings With Histology Using Magnetization Transfer Imaging and Multigradient Echo Magnetic Resonance Imaging. Invest Radiol. 2018. PMID: 30247172. doi:10.1097/RLI.0000000000000496
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。