文献速递腹部技术与安全US

点剪切波弹性成像用于肝纤维化分级:测量次数能否减少?

Point Shear Wave Elastography for Grading Liver Fibrosis: Can the Number of Measurements Be Reduced?
PubMed 文献 · Ultrasound Med Biol · 2018-09-14

本研究回顾性分析3401例肝病患者肝段8的点剪切波弹性成像检查,每例连续完成10次有效测量。比较10次测量中位数与仅用前1–9次测量进行肝纤维化分级的差异,结果显示用5–9次与10次分级高度相关(τ=0.96/0.95,p<0.001),用5次时仅2.6%检查的二分类分级发生改变,且仅见于速度1.1–1.5 m/s时,提示减少测量次数可行。

要点

  • 使用5–9次有效测量与10次测量进行肝纤维化分级高度相关(τ=0.96/0.95)。
  • 仅用5次测量时,3401例中87例(2.6%)二分类分级改变,且仅发生在速度1.1–1.5 m/s。
  • 减少至5–9次有效测量可能有助于缩短扫描时间、降低成本和不适。

核心结论

  • 肝点剪切波弹性成像使用5–9次有效测量与10次测量相比,肝纤维化分级误分类比例小,可能有助于减少扫描时间、成本和不适。

研究设计与样本

  • 回顾性研究,纳入3401例肝病患者的点剪切波弹性成像检查,每例在肝段8连续完成10次有效测量;以已发表截断值进行肝纤维化分级,比较10次测量中位数与前1–9次测量中位数的分级一致性(Kendall's τ系数)。

诊断标准与关键数值

  • 使用5–9次与10次有效测量进行总体及二分类(临床显著纤维化≥F2 vs 非显著F0/F1)分级高度相关,τ=0.96/0.95,p<0.001;使用5次测量时,3401例检查中87例(2.6%)二分类分级发生改变,且仅当测得速度在1.1–1.5 m/s之间时出现。

临床应用与阅片要点

  • 作者认为肝点剪切波弹性成像使用5–9次有效测量与10次测量相比仅导致小部分肝纤维化分级误分类,可能有助于缩短扫描时间、降低成本和减轻超声医师与患者的不适。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of this study was to assess whether the number of liver point shear wave elastography (pSWE) measurements could be reduced compared with the currently recommended 10 valid measurements. Three thousand four hundred one pSWE examinations in patients with liver disease were performed with 10 consecutive valid measurements in liver segment 8. Liver fibrosis grading using published cutoff values were compared retrospectively using the median of 10 versus the first 1-9 measurements with Kendall's τ coefficient. Overall and binary (clinically significant [≥F2] versus non-significant [F0/F1]) fibrosis grading highly correlated when using 5-9 versus 10 valid measurements (τ = 0.96/0.95, p < 0.001). With the use of 5 valid measurements, a change in binary grading was observed in 87 of 3401 (2.6%) exams and only when velocities measured between 1.1 and 1.5 m/s. Therefore, using 5-9 valid measurements in pSWE of the liver results in a small portion of liver fibrosis grading misclassifications compared with use of 10 measurements and could help decrease scanning time, cost and discomfort in sonographers and patients.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Durot I, Akhbardeh A, Rosenberg J, et al. Point Shear Wave Elastography for Grading Liver Fibrosis: Can the Number of Measurements Be Reduced? Ultrasound Med Biol. 2018. PMID: 30224172. doi:10.1016/j.ultrasmedbio.2018.07.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。