扩散峰度磁共振成像直方图分析用于肝纤维化诊断
研究采用3T磁共振对36只大鼠(四氯化碳诱导纤维化组与对照组)行扩散峰度成像直方图分析,35只纳入分析并分为F0-F4期。D图均值、中位数、25及75百分位数、峰度,K图中位数、25百分位数、偏度及ADC图75百分位数与纤维化分期显著相关;D图AUC大于K图和ADC图,但两两比较无显著差异。结论认为DKI直方图分析较ADC提供附加价值和更好的诊断性能。
要点
- D图直方图参数(均值、中位数、25及75百分位数、峰度)与肝纤维化分期显著相关。
- 纤维化评分是直方图参数的独立相关变量,除K图中位数外均优于炎症活动分级。
- D图在各期纤维化分期中AUC大于K图和ADC图,但两两比较无显著差异。
核心结论
- DKI直方图分析的矫正表观扩散(D)较ADC提供附加价值和更好的诊断性能,用于检测各期肝纤维化。
研究设计与样本
- 动物实验:36只大鼠分为四氯化碳诱导纤维化组(2、4、6、8周各6只)和对照组(12只),最终35只纳入分析。
- 使用3T磁共振扫描仪行MRI检查,获取DKI直方图(D、K及ADC图)。
- 参考标准为纤维化分期(F0-F4)和炎症活动分级。
诊断标准与关键数值
- 35只大鼠中诊断为F0、F1、F2、F3、F4者分别为12、5、5、6、7只。
- D图均值、中位数、25及75百分位数、峰度,K图中位数、25百分位数、偏度,以及ADC图75百分位数与纤维化分期显著相关(r=-0.767至0.339,p<0.001至p=0.039)。
- 纤维化评分是直方图参数的独立相关变量(p<0.001至p=0.041),但K图中位数除外(p=0.185)。
- D图在各期纤维化分期的AUC大于K图和ADC图,但两两比较无显著差异(p=0.0512至p=0.847)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the diagnostic value of diffusion kurtosis imaging (DKI) histogram analysis in hepatic fibrosis staging.
MATERIALS AND METHODS: Thirty-six rats were divided into carbon tetrachloride-induced fibrosis groups (6 rats per group for 2, 4, 6, and 8 weeks) and a control group (n = 12). MRI was performed using a 3T scanner. Histograms of DKI were obtained for corrected apparent diffusion (D), kurtosis (K) and apparent diffusion coefficient (ADC). Mean, median, skewness, kurtosis and 25th and 75th percentiles were generated and compared according to the fibrosis stage and inflammatory activity.
RESULTS: A total of 35 rats were included, and 12, 5, 5, 6, and 7 rats were diagnosed as F0-F4. The mean, median, 25th and 75th percentiles, kurtosis of D map, median, 25th percentile, skewness of K map, and 75th percentile of ADC map demonstrated significant correlation with fibrosis stage (r = -0.767 to 0.339, p < 0.001 to p = 0.039). The fibrosis score was the independent variable associated with histogram parameters compared with inflammatory activity grade (p < 0.001 to p = 0.041), except the median of K map (p = 0.185). Areas under the receiver operating characteristic curve of D were larger than K and ADC maps in fibrosis staging, although no significant differences existed in pairwise comparisons (p = 0.0512 to p = 0.847).
CONCLUSION: Corrected apparent diffusion of DKI histogram analysis provides added value and better diagnostic performance to detect various liver fibrosis stages compared with ADC.
引用
- Sheng RF, Jin KP, Yang L, et al. Histogram Analysis of Diffusion Kurtosis Magnetic Resonance Imaging for Diagnosis of Hepatic Fibrosis. Korean J Radiol. 2018. PMID: 30174481. doi:10.3348/kjr.2018.19.5.916
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。