全碘常规CT与半碘虚拟单色成像的比较:优势与劣势
回顾性比较21例患者全碘(600 mg/kg)常规CT与半碘(300 mg/kg)虚拟单色成像(VMI)对腹部动脉的显示质量,发现两种扫描主动脉、腹腔干和肠系膜上动脉CT衰减无显著差异,VMI的CNR更高但CTDI更高,且VMI对小血管显示更差、空间分辨率降低。
要点
- 半碘VMI与全碘常规CT对主动脉、腹腔干和肠系膜上动脉主干的显示无显著差异。
- VMI对胃十二指肠动脉、胰周动脉弓、肠系膜上动脉分支、边缘动脉和直血管的显示显著差于常规CT。
- VMI的CTDI显著高于常规CT,且半碘VMI空间分辨率降低。
核心结论
- 全碘常规CT与半碘VMI对大血管的显示和CNR相当,但VMI不能清晰显示小动脉且需要更大的辐射剂量。
研究设计与样本
- 回顾性研究纳入21例(男10例,女11例;平均年龄73.9岁)同时接受全碘(600 mg/kg)常规CT和半碘(300 mg/kg)VMI的患者,比较CT衰减、CNR、CTDI,并由两名委员会认证的诊断放射科医师评估最大强度投影图像上腹腔干和肠系膜上动脉主干及分支的可视化,另用丙烯酸体模评估空间分辨率。
关键影像表现/征象
- 主动脉、腹腔干和肠系膜上动脉的CT衰减在两种扫描间无显著差异。
- 主动脉和腹腔干的CNR在VMI显著更高(分别为p=0.011和p=0.030)。
- VMI的CTDI显著更高(p=0.024)。
- 腹腔干和肠系膜上动脉主干的可视化无显著差异,但胃十二指肠动脉、胰周动脉弓、肠系膜上动脉分支、边缘动脉和直血管的可视化在常规扫描显著更好(p<0.001)。
- 计算的调制传递函数(MTF)提示半碘VMI空间分辨率降低。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare image quality of abdominal arteries between full-iodine-dose conventional CT and half-iodine-dose virtual monochromatic imaging (VMI).
MATERIALS AND METHODS: We retrospectively evaluated images of 21 patients (10 men, 11 women; mean age, 73.9 years) who underwent both full-iodine (600 mg/kg) conventional CT and half-iodine (300 mg/kg) VMI. For each patient, we measured and compared CT attenuation and the contrast-to-noise ratio (CNR) of the aorta, celiac artery, and superior mesenteric artery (SMA). We also compared CT dose index (CTDI). Two board-certified diagnostic radiologists evaluated visualisation of the main trunks and branches of the celiac artery and SMA in maximum-intensity-projection images. We evaluated spatial resolution of the two scans using an acrylic phantom.
RESULTS: The two scans demonstrated no significant difference in CT attenuation of the aorta, celiac artery, and SMA, but CNRs of the aorta and celiac artery were significantly higher in VMI (p = 0.011 and 0.030, respectively). CTDI was significantly higher in VMI (p = 0.024). There was no significant difference in visualisation of the main trunk of the celiac artery and SMA, but visualisation of the gastroduodenal artery, pancreatic arcade, branch of the SMA, marginal arteries, and vasa recta was significantly better in the conventional scan (p < 0.001). The calculated modular transfer function (MTF) suggested decreased spatial resolution of the half-iodine VMI.
CONCLUSION: Large-vessel depiction and CNRs were comparable between full-iodine conventional CT and half-iodine VMI images, but VMI did not permit clear visualisation of small arteries and required a larger radiation dose.
KEY POINTS: ・Reducing the dose of iodine contrast medium is essential for chronic kidney disease patients to prevent contrast-induced nephropathy. ・In virtual monochromatic images at low keV, contrast of relatively large vessels is maintained even with reduced iodine load, but visibility of small vessels is impaired with decreased spatial resolution. ・We should be aware about the advantages and disadvantages associated with virtual monochromatic imaging with reduced iodine dose.
引用
- Sugawara H, Suzuki S, Katada Y, et al. Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol. 2018. PMID: 30209591. doi:10.1007/s00330-018-5724-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。