文献速递腹部US

点剪切波弹性成像无创评估病毒性肝炎患者肝纤维化

Point Shear Wave Elastography for Non-invasive Assessment of Liver Fibrosis in Patients with Viral Hepatitis.
PubMed 文献 · Ultrasound Med Biol · 2018-09-18

研究评估ElastPQ对217例慢性病毒性肝炎患者肝纤维化的诊断准确性,以瞬时弹性成像为参考标准。ElastPQ诊断显著纤维化(≥F2)的AUROC为0.843,诊断肝硬化(F4)的AUROC为0.933;F2最佳阈值6.68 kPa,F4最佳阈值11.28 kPa。结论认为ElastPQ是无创分期肝纤维化的准确工具。

要点

  • ElastPQ诊断肝硬化(F4)的AUROC为0.933,阈值11.28 kPa时敏感度86.0%、特异度85.6%。
  • ElastPQ诊断显著纤维化(≥F2)的AUROC为0.843,阈值6.68 kPa时敏感度80.7%、特异度70.4%。
  • F4阈值11.28 kPa的阴性预测值达97.16%,有助于排除肝硬化。

核心结论

  • ElastPQ是无创分期病毒性肝炎患者肝纤维化的准确工具。

研究设计与样本

  • 研究纳入217例慢性病毒性肝炎患者,平均年龄49±0.79岁,男性占68.2%,以瞬时弹性成像为参考标准(F0/F1<7.1 kPa,F2 7.1-9.4 kPa,F3 9.5-12.4 kPa,F4≥12.5 kPa),采用AUROC分析评估ElastPQ对≥F2和F4的诊断阈值。

诊断标准与关键数值

  • ElastPQ诊断≥F2的AUROC为0.843(95%CI 0.791-0.895),最佳阈值6.68 kPa,敏感度80.7%、特异度70.4%、阳性预测值78.5%、阴性预测值72.3%;诊断F4的AUROC为0.933(95%CI 0.894-0.972),最佳阈值11.28 kPa,敏感度86.0%、特异度85.6%、阳性预测值60.52%、阴性预测值97.16%。

临床应用与阅片要点

  • 作者认为ElastPQ可作为病毒性肝炎患者肝纤维化无创分期的准确工具,报告中可参考≥F2阈值6.68 kPa和F4阈值11.28 kPa及其对应的敏感度、特异度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Elastography point quantification (ElastPQ) is a new ultrasound-based shear wave elastography method for non-invasive assessment of liver fibrosis. We evaluated the diagnostic accuracy of ElastPQ in patients with chronic viral hepatitis. Fibrosis stage (F) was determined by transient elastography (F0/F1: <7.1 kPa, F2: 7.1-9.4 kPa, F3: 9.5-12.4 kPa, F4: ≥12.5 kPa). Area under the receiver operator characteristics curve (AUROC) analysis was performed to assess ElastPQ cutoffs for significant fibrosis (≥F2) and cirrhosis (F4). Paired transient elastography and ElastPQ measurements were obtained from 217 patients (mean age ± SEM: 49 ± 0.79 years, 68.2% male, F0/F1: n = 98 [45.0%], F2: 47 [21.6%], F3: 22 [10.1%], F4: 50 [22.9%]). AUROC for ≥F2 was 0.843 (95% confidence interval: 0.791-0.895), and for F4, 0.933 (95% confidence interval: 0.894-0.972). The optimal ElastPQ cutoff for F2 was 6.68 kPa (sensitivity: 80.7%, specificity: 70.4%, positive predictive value: 78.5%, negative predictive value: 72.3%), and for F4 11.28 kPa (sensitivity: 86.0%, specificity: 85.6%, positive predictive value: 60.52%, negative predictive value: 97.16%). In conclusion, ElastPQ represents an accurate tool for non-invasive staging of liver fibrosis in patients with viral hepatitis.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Bucsics T, Grasl B, Ferlitsch A, et al. Point Shear Wave Elastography for Non-invasive Assessment of Liver Fibrosis in Patients with Viral Hepatitis. Ultrasound Med Biol. 2018. PMID: 30241728. doi:10.1016/j.ultrasmedbio.2018.07.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。