用于生理盐水冲洗的螺旋流生成管可改善Gd-EOB-DTPA增强肝脏MRI的主动脉强化

Spiral flow-generating tube for saline chaser improves aortic enhancement in Gd-EOB-DTPA-enhanced hepatic MRI.
PubMed 文献 · Eur Radiol · 2018-09-25

回顾性观察104例肝脏动态MRI患者,比较三种Gd-EOB-DTPA注射方案。螺旋管冲洗法(方案C)的腹主动脉SNR和对比度评分显著高于常规法(方案A),螺旋稀释法(方案B)与方案A无显著差异,三组伪影无显著差异。

要点

  • 螺旋管冲洗法较常规法提高肝动脉期腹主动脉SNR(25.4 vs 20.8)和对比度评分。
  • 螺旋稀释法与常规法在SNR和对比度评分上无显著差异。
  • 三种注射方案的伪影评分无显著差异。

核心结论

  • 使用螺旋管配合慢速注射方案有助于改善Gd-EOB-DTPA增强肝脏MRI肝动脉期的主动脉对比强化。

研究设计与样本

  • 回顾性研究,纳入2017年10月至2017年12月间接受肝脏动态MRI的104例患者,比较三种Gd-EOB-DTPA注射方案。

关键影像表现/征象

  • 方案C(螺旋管冲洗法:未稀释Gd-EOB-DTPA,注射速率1 ml/s,经螺旋管,n=30)的腹主动脉SNR为25.4 ± 8.8,方案A(常规法:未稀释Gd-EOB-DTPA,注射速率1 ml/s,n=36)为20.8 ± 5.4,方案C显著高于方案A(p=0.01)。
  • 方案B(螺旋稀释法:Gd-EOB-DTPA与生理盐水1:1稀释[超说明书使用],注射速率2 ml/s,经螺旋管,n=38)与方案A的SNR无显著差异(p=0.47)。
  • 方案C的对比度评分显著高于方案A(p=0.0019),方案B与方案A的对比度评分无显著差异(p=0.50)。
  • 三种方案的伪影评分无显著差异(p=0.96)。

诊断标准与关键数值

  • 腹主动脉SNR基于动脉期图像计算。
  • 图像对比度和伪影由两名委员会认证的放射科医生采用四分制量表评估。

临床应用与阅片要点

  • 肝动脉期图像上,采用螺旋管冲洗法(方案C)可观察到腹主动脉SNR和对比度评分较常规法(方案A)提高。
  • 螺旋稀释法(方案B)与常规法(方案A)在SNR和对比度评分上无显著差异。
  • 螺旋管冲洗法未显示减少伪影的作用,三种方案伪影评分无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effect of a spiral tube on contrast enhancement in the hepatic arterial phase (HAP) of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI).

METHODS: In this retrospective study, we observed 104 patients who underwent dynamic MRI of the liver between October 2017 and December 2017. Three Gd-EOB-DTPA injection protocols were compared: (A) conventional method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s, n = 36); (B) spiral dilution method (1:1 diluted Gd-EOB-DTPA with saline [off-label], injection rate 2 ml/s via spiral tube, n = 38); (C) spiral-flushed method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s via spiral tube, n = 30). We regarded protocol-A as a control. The signal-to-noise ratio (SNR) of the abdominal aorta was calculated using arterial phase images. Image contrast and artefacts were evaluated by two board-certified radiologists, using a four-point scale. Statistical analyses included Dunnett's test, the Kruskal-Wallis test and the Steel test.

RESULTS: The SNR of the aorta was significantly higher with protocol-C (25.4 ± 8.8) than protocol-A (20.8 ± 5.4, p = 0.01). There was no significant difference in SNR between protocols A and B (p = 0.47). The contrast score of protocol-C was significantly higher than that of protocol-A (p = 0.0019). There was no significant difference in contrast score between protocols A and B (p = 0.50). There was no significant difference in artefacts among the three protocols (p = 0.96).

CONCLUSIONS: Use of a spiral tube with a slow injection protocol contributed to improved aortic contrast enhancement in the HAP of GD-EOB-DTPA-enhanced hepatic MRI.

KEY POINTS: • Gadoxetic acid shows weaker arterial enhancement at recommended doses, compared with nonspecific gadolinium agents; selection of an appropriate injection protocol is important. • A spiral flow-generating tube improves the transport efficiency of the contrast media, and increases the signal-to-noise ratio of the aorta in hepatic arterial phase. • A spiral flow-generating tube does not contribute to artefact reduction in hepatic arterial phase.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Iyama A, Nakaura T, Iyama Y, et al. Spiral flow-generating tube for saline chaser improves aortic enhancement in Gd-EOB-DTPA-enhanced hepatic MRI. Eur Radiol. 2018. PMID: 30255255. doi:10.1007/s00330-018-5733-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。