使用16厘米宽探测器对屏气困难患者行自由呼吸冠状动脉CT血管成像:与有创冠状动脉造影的比较
纳入76例无法屏气患者(62%心率>75次/分或心律失常),行自由呼吸冠状动脉CT血管成像(CCTA)与有创冠状动脉造影(ICA)对比。CCTA诊断准确率在节段水平为90.8%、血管水平为93.4%、患者水平为92.1%。作者认为16厘米宽探测器自由呼吸CCTA对挑战性患者检测冠状动脉狭窄具有高准确率。
要点
- 节段水平诊断准确率90.8%,敏感度88.3%,特异度91.1%。
- 患者水平敏感度100%,特异度85%,阴性预测值100%。
- 高心率或心律失常患者81%节段可评估,诊断效能与总体无显著差异。
核心结论
- 作者结论:使用16厘米宽探测器CT的自由呼吸CCTA对挑战性患者检测冠状动脉狭窄与ICA相比具有高准确率。
研究设计与样本
- 单臂诊断准确性研究,纳入76例无法屏气患者,其中62%心率>75次/分或心律失常。
- 所有患者均接受自由呼吸CCTA与有创冠状动脉造影(ICA),以ICA为参考标准。
- 两名阅片者按节段、血管、患者三个水平评估图像质量(四分法)和狭窄程度。
关键影像表现/征象
- 1368个节段中228个(16.7%)因直径<1.5 mm被排除。
- 32个(2.3%)节段因钙化、26个(1.9%)因运动伪影在CT上判为阳性。
诊断标准与关键数值
- 节段水平:准确率90.8%,敏感度88.3%,特异度91.1%,阳性预测值57.1%,阴性预测值98.3%。
- 血管水平:准确率93.4%,敏感度90.6%,特异度94.2%,阳性预测值80.5%,阴性预测值97.4%。
- 患者水平:准确率92.1%,敏感度100%,特异度85%,阳性预测值85.7%,阴性预测值100%。
- 高心率或心律失常患者81%节段可评估(总体79.1%),其准确率、敏感度、特异度、阳性预测值、阴性预测值与总体人群统计学相同。
临床应用与阅片要点
- 对无法屏气且心率>75次/分或心律失常的患者,可参考本研究的节段、血管、患者水平诊断效能解读自由呼吸宽探测器CCTA。
- 判读时注意直径<1.5 mm节段被排除,钙化和运动伪影节段在CT上判为阳性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the superiority of free-breathing coronary computed tomography angiography (CCTA) with 16-cm wide-detector CT for challenging patients who cannot hold their breath.
MATEIALS AND METHODS: A total of 76 patients (62% with either heart rate >75 beats/min or arrhythmia) who were unable to breath-hold underwent both free-breathing CCTA and invasive coronary angiography (ICA) were included. Two reviewers evaluated coronary arteries on a per-segment, per-vessel, and per-patient basis for image quality using a four-point scale and stenosis degree. CCTA results were compared with ICA to calculate the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).
RESULTS: Out of 1,368 segments, 228 (16.7%) were <1.5 mm in diameter and were excluded. Thirty-two (2.3%) with calcification and 26 (1.9%) with motion artefacts were considered positive at CT. One thousand and eighty-two segments (79.1%) were evaluated both on CCTA and ICA, and 128 (11.8%) segments had ≥50% stenosis on ICA. The diagnostic accuracy, sensitivity, specificity, PPV, and NPV of CCTA were 90.8%, 88.3%, 91.1%, 57.1%, and 98.3% on a per-segment basis; 93.4%, 90.6%, 94.2%, 80.5% and 97.4% on a per-vessel basis; and 92.1%, 100%, 85%, 85.7% and 100% on a per-patient basis. For patients with high heart rates or arrhythmia, 81% (versus 79.1%) segments were evaluable, and the accuracy, sensitivity, specificity, PPV, and NPV were statistically the same as the entire study population.
CONCLUSION: Free-breathing CCTA using 16-cm wide-detector CT has high accuracy compared to ICA for detecting coronary artery stenosis for challenging patients.
引用
- Shuai T, Deng L, Pan Y, et al. Free-breathing coronary CT angiography using 16-cm wide-detector for challenging patients: comparison with invasive coronary angiography. Clin Radiol. 2018. PMID: 30195722. doi:10.1016/j.crad.2018.06.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。