文献速递心血管外周血管介入DSA

双平面与单平面血管造影:成人心脏诊断检查中对比剂用量与辐射剂量的比较研究

Bi-plane and single plane angiography: a study to compare contrast usage and radiation doses for adult cardiac patients in diagnostic studies.
PubMed 文献 · Br J Radiol · 2018-09-21

该回顾性研究纳入澳大利亚布里斯班某医院的5176例成人诊断性心脏血管造影,比较双平面与单平面冠状动脉造影的对比剂用量和剂量面积乘积(DAP)。双平面成像平均对比剂用量减少15.1 ml(15.5%,95%CI -13.2至-17.0,p<0.001),多因素回归显示减少27.0 ml(28%,95%CI -29.0至-24.83,p<0.0001);但DAP平均增加887.1 μGym2(23%,95%CI +1110.7至+663.4,p<0.001),多因素回归显示增加628.3 μGym2(16%,95%CI +467.5至+789.3,p<0.001)。作者认为双平面成像以更多辐射为代价减少对比剂用量,肾功能损害患者可能更适合双平面,无肾功能损害者可能更适合单平面。

要点

  • 双平面冠状动脉造影较单平面平均减少对比剂用量15.1 ml(15.5%,p<0.001),多因素校正后减少27.0 ml(28%,p<0.0001)。
  • 双平面成像的DAP较单平面平均增加887.1 μGym2(23%,p<0.001),多因素校正后增加628.3 μGym2(16%,p<0.001)。
  • 作者认为肾功能损害患者可能更适合双平面成像,无肾功能损害者可能更适合单平面成像。

核心结论

  • 双平面成像在冠状动脉造影中比单平面成像使用更少的对比剂,但辐射剂量更高。
  • 肾功能损害患者可能更适合双平面成像,无肾功能损害者可能更适合单平面成像。

研究设计与样本

  • 回顾性研究,纳入澳大利亚布里斯班某医院5176例成人诊断性心脏血管造影。
  • 排除有主动脉造影、髂动脉或股动脉成像以及支架或移植介入的患者。
  • 使用Student t检验比较均值,并使用多因素回归比较混杂变量,量化双平面系统使用的影响,同时保持BMI、年龄、房间、性别、数字采集次数和透视时间等其他因素不变。

诊断标准与关键数值

  • 双平面成像对比剂用量平均差异为-15.1 ml(15.5%,95%CI -13.2至-17.0,p<0.001)。
  • 多因素回归显示,在透视时间、数字采集次数、BMI和性别的显著效应保持不变时,双平面成像对比剂用量减少27.0 ml(28%,95%CI -29.0至-24.83,p<0.0001)。
  • 双平面成像DAP平均差异为+887.1 μGym2(23%,95%CI +1110.7至+663.4,p<0.001)。
  • 多因素回归显示,在透视时间、数字采集次数、BMI和性别的显著效应保持不变时,双平面成像DAP增加628.3 μGym2(16%,95%CI +467.5至+789.3,p<0.001)。

临床应用与阅片要点

  • 作者认为,肾功能损害患者可能更适合双平面成像,无肾功能损害者可能更适合单平面成像。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: This study compares the performance of bi-plane coronary angiography against single plane angiography in terms of the volume of contrast used (ml) and the total dose-area product (DAP) (μGym2) to the patient measured directly via flat panel detectors.

METHODS:: A total of 5176 adult diagnostic cardiac angiograms from a hospital in Brisbane, Australia were retrospectively studied. Patients with aortograms, iliac or femoral artery imaging, and stenting or graft interventions were excluded. Student's t-tests were used to compare means, and confounding variables were compared using multivariate regression. This quantified the effects of bi-plane system use holding constant other factors (e.g.) body mass index (BMI), age, room, sex, number of digital acquisitions and fluoro time.

RESULTS:: Bi-plane imaging had an average difference in mean contrast use of -15.1 ml [15.5% 95% confidence interval (CI) (-13.2, -17.0) p<0.001], multivariate regression demonstrated a -27.0 ml reduction in contrast use [28% 95% CI (-29.0, -24.83) p<0.0001] when the significant effects of fluoro time, number of digital acquisitions, BMI and sex were held constant. Bi-plane imaging had an average difference in mean DAP of + 887.1 μGym2 [23% 95% CI (+1110.7, +663.4) p < 0.001], whilst multivariate regression found a +628.3 Gym2 increase in DAP [16% 95% CI (+467.5, +789.3) p<0.001] when the significant effects of fluoro time, number of digital acquisitions, BMI and sex were held constant.

CONCLUSION:: These results demonstrate that bi-plane imaging uses less contrast media than single-plane imaging for coronary angiography at the expense of more radiation. Bi-plane imaging may be preferable in patients with renal impairment, however single plane imaging may be preferable in those without renal impairment.

ADVANCES IN KNOWLEDGE:: This is a large cohort and statistically comprehensive study comparing bi-plane and single plane coronary angiography. Other studies 4, 5, 6, 12 have used Student's t-tests to measure the difference between means, however this provides no causative information on the differences found. This study provides a view of the causative impact of bi-plane usage on DAP and contrast use via multivariate regression modelling.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Smith K, Crowhurst J, Walters D, et al. Bi-plane and single plane angiography: a study to compare contrast usage and radiation doses for adult cardiac patients in diagnostic studies. Br J Radiol. 2018. PMID: 30209953. doi:10.1259/bjr.20180367

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。